High-voltage Differential Active Probes (continued)
N2804A/N2805A high-voltage high-speed differential probes
The N2804A and N2805A differential probes provide the superior general-purpose
differential signal measurements that are required for high-speed power measurements
such as measuring characteristics of switching power devices, DC-DC converters or
class D amplifiers, vehicle bus measurements, and high-speed digital system designs.
The N2804A 300-MHz differential probe offers 100:1 attenuation ratio, allowing it to be
used adequately for high voltage signal measurements. The differential probe has a
differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit
loading. The probe comes with a pair of extension leads (30 cm long) with a damping
resistor built-in to damp out the in-band resonance and provide flat frequency response
even while using the extension leads and probe tip accessories.
The N2805A is a 200-MHz differential probe designed to provide superior differential
signal measurements with long cable length (5 m), making it ideal in an environment
where extended cable length is required. This probe comes with an extensive set of
probe tip accessories for use with small and large components in tight spaces.
N2804A 300 MHz differential probe
Characteristics for N2804A and N2805A
N2804A
N2805A
Bandwidth
Attenuation ratio
CMRR
Input impedance
(between inputs)
Max input voltage
(between two inputs)
Max input voltage
Cable length
Max number of probes
supported by InfiniiVision
Series
Compatible InfiniiVision
oscilloscopes
300 MHz (without extension leads)
120 MHz (with extension leads)
100:1
-80 dB at 50/60 Hz
-75 dB at 1 MHz
4 MΩ // 4 pF
200 MHz
50:1
-75 dB at 50/60 Hz
-80 dB at 1 MHz
4 MΩ // 4 pF
±300 V (DC+ peak AC) and ±200
Vrms
±300 V (DC+ peak AC) and ±200
Vrms CATII
±1000 V (DC+ peak AC) and ±1000
Vrms CATI
1.2 m
4
±200 V (DC+ peak AC) and ±200
Vrms CAT II
±500 V (DC+ peak AC) and ±500
Vrms CAT I
±300 V (DC+ peak AC) and ±200
Vrms CATII
5m
4
4000X Series with software 4.0 or higher, 3000X Series with software
2.38 or higher
For more information about the N7020A power rail probe, check out the Keysight data
sheet with the publication number 5992-0141EN.