EP2AGZ225HF40I3N Datasheet, PDF (48/382 Pages) Altera Corporation – Volume 1: Device Interfaces and Integration | |||
|
◁ |
2â18
Chapter 2: Logic Array Blocks and Adaptive Logic Modules in Arria II Devices
Document Revision History
â Clocks represent a significant portion of dynamic power consumption due to their
high switching activity and long paths. The LAB clock that distributes a clock
signal to registers within an LAB is a significant contributor to overall clock power
consumption. Each LABâs clock and clock enable signal are linked. For example, a
combinational ALUT or register in a particular LAB using the labclk1 signal also
uses the labclkena1 signal. To disable an LAB-wide clock power consumption
without disabling the entire clock tree, use the LAB-wide clock enable to gate the
LAB-wide clock. The Quartus II software automatically promotes register-level
clock enable signals to the LAB-level. All registers within the LAB that share a
common clock and clock enable are controlled by a shared, gated clock. To take
advantage of these clock enables, use a clock-enable construct in your HDL code
for the registered logic.
f For more information about implementing static and dynamic power consumption
within the LAB, refer to the Power Optimization chapter in volume 2 of the Quartus II
Handbook.
Document Revision History
Table 2â1 lists the revision history for this document.
Table 2â1. Document Revision History
Date
December 2010
June 2009
February 2009
Version
Changes
Updated for the Quartus II software version 10.1 release:
â Added Arria II GZ device information.
2.0
â Updated âLogic Array Blocksâ, âLAB Interconnectsâ, âLAB Control Signalsâ, âAdaptive
Logic Modulesâ, âALM Operating Modesâ, âNormal Modeâ sections.
â Added Figure 2â7 and Figure 2â8.
â Added âLAB Power Management Techniquesâ section.
1.1 Updated Figure 2â6.
1.0 Initial Release.
Arria II Device Handbook Volume 1: Device Interfaces and Integration
December 2010 Altera Corporation
|
▷ |