Chapter 9: Configuration, Design Security, and Remote System Upgrades in Arria II Devices
Remote System Upgrades
Figure 9â21 shows the steps required for performing remote configuration updates.
(The numbers in Figure 9â21 coincide with the steps just mentioned.)
Figure 9â21. Functional Diagram of Arria II Remote System Upgrade
2
1
Development
Location
Data
Data
Data
Arria II Device
Control Module
3
Configuration
Memory
Arria II Configuration
4
1 Arria II devices only support remote system upgrade in the single device AS
configuration scheme.
Figure 9â22 shows a block diagram for implementing a remote system upgrade with
the Arria II configuration scheme.
Figure 9â22. Remote System Upgrade Block Diagram for Arria II Configuration Scheme (Note 1)
Arria II Device
Nios II Processor
or User Logic
Serial
Configuration
Device
Note to Figure 9â22:
(1) Arria II GX devices use the AS configuration scheme while Arria II GZ devices use the fast AS configuration scheme.
You must set the mode select MSEL[3..0] pins to AS mode to use the remote system
upgrade feature for Arria II GX devices and the MSEL[2..0] pins to fast AS mode to
use the remote system upgrade feature for Arria II GZ devices.
1 The MSEL pin settings vary for different configuration voltage standards and POR
delays. To connect MSEL[3..0] for an Arria II GX device, refer to Table 9â6 on
page 9â9. To connect MSEL[2..0] for an Arria II GZ device, refer to Table 9â7 on
page 9â10.
1 When using AS mode, you must select remote update mode in the Quartus II
software and insert the ALTREMOTE_UPDATE megafunction to access the circuitry.
For more information, refer to âALTREMOTE_UPDATE Megafunctionâ on page 9â60.