English
Language : 

AK4636 Datasheet, PDF (95/105 Pages) Asahi Kasei Microsystems – 16-Bit Mono CODEC with ALC & MIC/SPK/Video-AMP
[AK4636]
■ MIC Input Recording
FS3-0 bits X,XXX
(Addr:05H,
D5,D2-0)
(1)
0,010
ADRST bit X
(Addr:05H, D7)
X
MIC Control
(Addr:02H, D2-0
Addr :03H, D5)
XXXX
(2)
ALC1 Control 1 XXH
(Addr:06H)
(3)
ALC1 Control 2
(Addr:08H)
IVOL7-0 bits
(Addr:09H)
ALC1 Control 3
(Addr:07H)
XXH
(4)
XXH
(5)
XXH
(6)
Signal Select
(Addr:03H)
XXH
(7)
Filter Co-ef
(Addr:10H-1F)
Filter Select
(Addr:11H D5-4, D0)
XX....X
XX1
(8)
(9)
ALC1 State
ALC1 Disable
0,001
14H
C5H
C5H
A1H
81H
XX....X
011
ALC1 Enable
ALC1 Disable
PMADC bit
(Addr:00H, D0)
PMPFIL bit
(Addr:00H, D7)
ADC Internal
State
(10)
(11)
291/fs or 1059/fs
Power Down
Initialize Normal State Power Down
Figure 75. MIC Input Recording Sequence
Example:
PLL Master Mode
Audio I/F Format: MSB justified
Sampling Frequency: 16kHz
Pre MIC AMP:+20dB
MIC Power On
ADC Initialize time: 291/fs
ALC1 setting:Refer to Table 36
HPF : ON (fc=150Hz)
4+1 band EQ : OFF
(1) Addr:05H, Data:02H
(2) Addr:02H, Data:05H
(3) Addr:06H, Data:14H
(4) Addr:08H, Data:C5H
(5) Addr:09H, Data:C5H
(6) Addr:07H, Data:A1H
(7) Addr:03H, Data:81H
(8-1) Addr:1CH, Data:A9H
(8-2) Addr:1DH, Data:1FH
(8-3) Addr:1EH, Data:53H
(8-4) Addr:1FH, Data:1FH
(9) Addr:11H, Data:11H
(10) Addr:00H, Data:C1H
Recording
(11) Addr:00H, Data:40H
<Example>
This sequence is an example of ALC1 setting at fs=16kHz. If the parameter of the ALC1 is changed, please refer to
the Figure 47.
At first, clocks should be supplied according to “Clock Set Up” sequence.
(1) Set up a sampling frequency (FS3-0 bit). When the AK4636 is in PLL mode, programmable filter and ADC
should be powered-up in consideration of PLL lock time after the sampling frequency is changed.
(2) Set up MIC input (Addr: 02H)
(3) Set up Timer Select for ALC1 (Addr: 06H)
(4) Set up REF value for ALC1 (Addr: 08H)
(5) Set up IVOL value for ALC1 (Addr: 09H)
(6) Set up LMTH0, RGAIN0, LMAT1-0, ZELM and ALC1 bits (Addr: 07H)
(7) Set up Programmable Filter Path: PFSDO bit = ADCPF bit = “1”
(8) Set up Coefficient of the Programmable Filter (HPF/EQ) Addr: 1CH ~ 1FH, 2CH ~ 2FH, 32H ~ 4FH
(9) Switch ON/OFF of the Programmable Filter
(10) Power-up of the ADC and Programmable Filter: PMPFIL bit = PMADC bit = “0” Æ “1”
The initialization cycle of the ADC is 1059/fs=24ms@fs=44.1kHz when ADRST bit = “0”,
291/fs=18ms@fs=16kHz when ADRST bit= “1”. ALC starts operating at the value set by IVOL (5).
(11) Power-down of the ADC and Programmable Filter: PMPFIL bit = PMADC bit = “1” Æ “0”
MS1012-E-01
- 95 -
2010/08