AMC7834 Datasheet, PDF (66/93 Pages) Texas Instruments – AMC7834 12-Bit Integrated Power-Amplifier Monitor and Control System with Temperature, Current and Voltage Supervision Capabilities
AMC7834
SLAS972B – NOVEMBER 2014 – REVISED MARCH 2016
7.6.7 Device Status: Address 0x1E and 0x1F
7.6.7.1 Alarm Status Register (address = 0x1E) [reset = 0x0000]
www.ti.com
Figure 84. Alarm Status Register (R)
15
DAC4-HIGH-
ALARM
R-0
14
DAC3-HIGH-
ALARM
R-0
13
DAC2-HIGH-
ALARM
R-0
12
DAC1-HIGH-
ALARM
R-0
11
Reserved
R-0
10
AVSS-ALARM
R-0
9
RT2-HIGH-
ALARM
R-0
8
RT2-LOW-
ALARM
R-0
7
RT1-HIGH-
ALARM
R-0
6
RT1-LOW-
ALARM
R-0
5
LT-HIGH-
ALARM
R-0
4
LT-LOW-
ALARM
R-0
3
ADCINT4/CS4-
ALARM
R-0
2
ADCINT3/CS3-
ALARM
R-0
1
ADCINT2/CS2-
ALARM
R-0
0
ADCINT1/CS1-
ALARM
R-0
Table 31. Alarm Status Register Field Descriptions
Bit Field
15
DAC4-HIGH-ALARM
14
DAC3-HIGH-ALARM
13
DAC2-HIGH-ALARM
12
DAC1-HIGH-ALARM
11
Reserved
10
AVSS-ALARM
9
RT2-HIGH-ALARM
8
RT2-LOW-ALARM
7
RT1-HIGH-ALARM
6
RT1-LOW-ALARM
5
LT-HIGH-ALARM
4
LT-LOW-ALARM
3
ADCINT4/CS4-ALARM
2
ADCINT3/CS3-ALARM
Type
R
R
R
R
R
R
R
Reset
0
0
0
0
0
0
0
R
0
R
0
R
0
R
0
R
0
R
0
R
0
Description
DAC4-HIGH-ALARM = 1 when DAC4 has exceeded the upper
output limit set by DAC34-UP-THRESH[11:0].
DAC3-HIGH-ALARM = 1 when DAC3 has exceeded the upper
output limit set by DAC34-UP-THRESH[11:0].
DAC2-HIGH-ALARM = 1 when DAC2 has exceeded the upper
output limit set by DAC12–UP-THRESH[11:0].
DAC1-HIGH-ALARM = 1 when DAC1 has exceeded the upper
output limit set by DAC12–UP-THRESH[11:0].
Reserved for factory use.
AVSS_ALARM = 1 when AVSS is out of range.
RT2-HIGH-ALARM = 1 when remote temperature sensor 2 is
out of the range defined by the upper threshold.
Always zero when the remote sensor is disabled.
RT2-LOW-ALARM = 1 when remote temperature sensor 2 is out
of the range defined by the lower threshold.
Always zero when the remote sensor is disabled.
RT1-HIGH-ALARM = 1 when remote temperature sensor 1 is
out of the range defined by the upper threshold.
Always zero when the remote sensor is disabled.
RT1-LOW-ALARM = 1 when remote temperature sensor 1 is out
of the range defined by the lower threshold.
Always zero when the remote sensor is disabled.
LT-HIGH-ALARM = 1 when the local temperature sensor is out
of the range defined by the upper threshold.
Always zero when the on-chip sensor is disabled.
LT-LOW-ALARM = 1 when the local temperature sensor is out
of the range defined by the lower threshold.
Always zero when the on-chip sensor is disabled.
ADCINT4/CS4-ALARM = 1 when the ADC reading of internal
channel 4 (closed-loop) or the measurement of current sense 4
(open-loop) is out of range defined by the alarm threshold
registers.
ADCINT3/CS3-ALARM = 1 when the ADC reading of internal
channel 3 (closed-loop) or the measurement of current sense 3
(open-loop) is out of range defined by the alarm threshold
registers.
66
Submit Documentation Feedback
Product Folder Links: AMC7834
Copyright © 2014–2016, Texas Instruments Incorporated