English
Language : 

AMC7834 Datasheet, PDF (57/93 Pages) Texas Instruments – AMC7834 12-Bit Integrated Power-Amplifier Monitor and Control System with Temperature, Current and Voltage Supervision Capabilities
www.ti.com
Bit Field
3-2 RT2-FALR[1:0]
1–0 RT1-FALR[1:0]
AMC7834
SLAS972B – NOVEMBER 2014 – REVISED MARCH 2016
Table 18. AMC Config1 Field Descriptions (continued)
Type
R/W
Reset
10
R/W
10
Description
False alarm protection for remote temperature sensor 2 (D2+,
D2–). Use the following configurations for the consecutive
samples before the alarm is set:
00: 1
01: 2
10: 4 (default)
11: 8
False alarm protection for remote temperature sensor 1 (D1+,
D1–). Use the following configurations for the consecutive
samples before the alarm is set:
00: 1
01: 2
10: 4 (default)
11: 8
7.6.3.3 ADC MUX Register (address = 0x12) [reset = 0x0000]
15
Reserved
R/W-0
7
ADCEXT4
R/W-0
14
LT
R/W-0
6
ADCEXT3
R/W-0
Figure 73. ADC MUX Register (R/W)
13
RT2
R/W-0
5
ADCEXT2
R/W-0
12
RT1
R/W-0
4
ADCEXT1
R/W-0
11
CS4
R/W-0
3
ADCINT4
R/W-0
10
CS3
R/W-0
2
ADCINT3
R/W-0
9
CS2
R/W-0
1
ADCINT2
R/W-0
8
CS1
R/W-0
0
ADCINT1
R/W-0
Bit Field
15
Reserved
14
LT
13
RT2
12
RT1
11
CS4
10
CS3
9
CS2
8
CS1
7
ADCEXT4
6
ADCEXT3
5
ADCEXT2
4
ADCEXT1
3
ADCINT4
2
ADCINT3
1
ADCINT2
0
ADCINT1
Table 19. ADC MUX Register Field Descriptions
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Description
When set to 1 the corresponding analog input channel to the
ADC mux is accessed during an ADC conversion cycle.
When cleared to 0 the corresponding input channel to the ADC
mux is ignored during an ADC conversion cycle.
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: AMC7834
Submit Documentation Feedback
57