8 Specifications
8.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
Input voltage
Output voltage
Input current
Sink current
Sink/Source Current
Output Voltage Continuos
Output Current Continuous
Current
BAT Operating Voltage
Junction Temperature
Storage Temperature, Tstg
IN
PMID, VINLS
CD, SDA, SCL, ILIM, ISET, IPRETERM, LSCTRL,
INT, RESET, TS
SYS
IN
INT
RESET
SW
SW
SYS, BAT
LS/LDO
VBAT, MR,
wrt GND
wrt GND
wrt GND
MIN
MAX
UNIT
–0.3
20
V
–0.3
7.7
V
–0.3
5.5
V
3.6
V
400
mA
10
mA
10
mA
–0.7
7.7
V
400
mA
300
mA
150
mA
6.6
V
–40
125
°C
300
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
8.2 ESD Ratings
V(ESD) Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2000
±500
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
8.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
VIN
V(BAT)
V(VINLS)
V(VINLS)
IIN
I(SW)
I(PMID)
ILS/LDO
I(BAT), I(SYS)
TJ
IN voltage range
IN operating voltage range, recommended
V(BAT) operating voltage range
VINLS voltage range for Load Switch
VINLS voltage range for LDO
Input Current, IN input
Output Current from SW, DC
Output Current from PMID, DC
Output Current from LS/LDO
Charging and discharging using internal battery FET
Operating junction temperature range
MIN
NOM
MAX UNIT
3.4
5
20
V
3.4
5
5.5
5.5 (1)
V
0.8
5.5 (2)
V
2.2
5.5
V
400
mA
300
mA
300
mA
100
mA
300
mA
–40
125
°C
(1) Any voltage greater than shown should be a transient event.
(2) These inputs will support 6.6 V for less than 10% of the lifetime at V(BAT) or VIN, with a reduced current and/or performance.
6
Submit Documentation Feedback
Product Folder Links: bq25120A