5.30 PMM, SVM Low Side
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
SVMLE = 0, PMMCOREV = 2
0
I(SVML)
SVML current consumption
SVMLE= 1, PMMCOREV = 2, SVMLFP = 0
200
SVMLE= 1, PMMCOREV = 2, SVMLFP = 1
1.5
SVMLE = 1, dVCORE/dt = 10 mV/µs,
SVMLFP = 1
2.5
tpd(SVML) SVML propagation delay
SVMLE = 1, dVCORE/dt = 1 mV/µs,
SVMLFP = 0
20
t(SVML)
SVML on or off delay time
SVMLE = 0 → 1, dVCORE/dt = 10 mV/µs,
SVMLFP = 1
SVMLE = 0 → 1, dVCORE/dt = 1 mV/µs,
SVMLFP = 0
12.5
100
MAX
UNIT
nA
nA
µA
µs
µs
5.31 Wakeup From Low-Power Modes and Reset
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
tWAKE-UP-FAST
Wake-up time from LPM2,
LPM3, or LPM4 to active
mode (1)
PMMCOREV = SVSMLRRL = n
(where n = 0, 1, 2, or 3),
SVSLFP = 1
fMCLK ≥ 4.0 MHz
1.0 MHz < fMCLK <
4.0 MHz
3.5 7.5
µs
4.5
9
tWAKE-UP-SLOW
Wake-up time from LPM2,
LPM3 or LPM4 to active
mode (2)
PMMCOREV = SVSMLRRL = n
(where n = 0, 1, 2, or 3),
SVSLFP = 0
150 175 µs
tWAKE-UP-LPM5
Wake-up time from LPM4.5
to active mode(3)
2
3 ms
tWAKE-UP-RESET
Wake-up time from RST or
BOR event to active mode(3)
2
3 ms
(1) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVSL) and low side monitor (SVML). Fastest wakeup times are possible with SVSLand SVML in full
performance mode or disabled when operating in AM, LPM0, and LPM1. Various options are available for SVSLand SVML while
operating in LPM2, LPM3, and LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx
and MSP430x6xx Family User's Guide (SLAU208).
(2) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVSL) and low side monitor (SVML). In this case, the SVSLand SVML are in normal mode (low current)
mode when operating in AM, LPM0, and LPM1. Various options are available for SVSLand SVML while operating in LPM2, LPM3, and
LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx and MSP430x6xx Family User's
Guide (SLAU208).
(3) This value represents the time from the wakeup event to the reset vector execution.
36