Analog-to-Digital Converter (ADC)
Bit/Field
23
22
21
20
19
Name
TS5
IE5
END5
D5
TS4
Type
RW
RW
RW
RW
RW
Reset
0
Description
6th Sample Temp Sensor Select
Value Description
0 The input pin specified by the ADCSSMUXn register is read
during the sixth sample of the sample sequence.
1 The temperature sensor is read during the sixth sample of the
sample sequence.
0
6th Sample Interrupt Enable
Value Description
0 The raw interrupt is not asserted to the interrupt controller.
1 The raw interrupt signal (INR0 bit) is asserted at the end of the
sixth sample's conversion. If the MASK0 bit in the ADCIM register
is set, the interrupt is promoted to the interrupt controller.
It is legal to have multiple samples within a sequence generate interrupts.
0
6th Sample is End of Sequence
Value Description
0 Another sample in the sequence is the final sample.
1 The sixth sample is the last sample of the sequence.
It is possible to end the sequence on any sample position. Software
must set an ENDn bit somewhere within the sequence. Samples defined
after the sample containing a set ENDn bit are not requested for
conversion even though the fields may be non-zero.
0
6th Sample Differential Input Select
Value Description
0 The analog inputs are not differentially sampled.
1 The analog input is differentially sampled. The corresponding
ADCSSMUXn nibble must be set to the pair number "i", where
the paired inputs are "2i and 2i+1".
Because the temperature sensor does not have a differential option,
this bit must not be set when the TS5 bit is set.
0
5th Sample Temp Sensor Select
Value Description
0 The input pin specified by the ADCSSMUXn register is read
during the fifth sample of the sample sequence.
1 The temperature sensor is read during the fifth sample of the
sample sequence.