English
Language : 

DS90UR910-Q1 Datasheet, PDF (11/34 Pages) Texas Instruments – 10 - 75 MHz 24-bit Color FPD-Link II to CSI-2 Converter
www.ti.com
5.7 DC and AC Serial Control Bus (CCI/I2C)
Over supply and temperature ranges unless otherwise specified. ( Figure 7)
Symbol
Parameter
Conditions
VIH
Input High Level
SDA and SCL
VIL
Input Low Level Voltage
SDA and SCL
VHY
Input Hysteresis
Fast mode, 3.3V I/O (1)
Fast mode, 1.8V I/O
VOL
Output Low Level Voltage
SDA, IOL = +1.5 mA
tR
SDA RiseTime – READ
Total capacitance of one bus line,
Cb ≤ 400pF
tF
SDA Fall Time – READ
Standard mode
Fast mode
tSU;DAT
Set Up Time – READ
Standard mode
Fast mode
tHD;DAT
tSP
Cin
Hold Up Time – READ
Input Filter
Input Capacitance
Fast mode
SDA and SCL
(1) Specification is ensured by characterization.
Ideal Data Bit
Beginning
Sampling
Window
DS90UR910-Q1
SNLS414D – JUNE 2012 – REVISED JULY 2015
Min
0.65*
VDDIO
GND
0.05*
VDDIO
0
250
100
0
Typ
0.1*
VDDIO
50
5
Max
VDDIO
0.35*
VDDIO
0.4
300
1000
300
Units
V
V
mV
mV
V
ns
ns
ns
ns
ns
ns
ns
pF
Ideal Data
Bit End
RxIN_TOL
Left
VTH
0V
RxIN_TOL
Right
VTL
Ideal Center Position (tBIT/2)
tBIT (1 UI)
tIJT = RxIN_TOL (Left + Right)
Sampling Window = 1 UI - tIJT
Figure 1. Receiver Input Jitter Tolerance
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DS90UR910-Q1
Submit Documentation Feedback
11