English
Language : 

DS90UR910-Q1 Datasheet, PDF (10/34 Pages) Texas Instruments – 10 - 75 MHz 24-bit Color FPD-Link II to CSI-2 Converter
DS90UR910-Q1
SNLS414D – JUNE 2012 – REVISED JULY 2015
AC Switching Characteristics (continued)
Over recommended operating supply and temperature ranges unless otherwise specified.
Symbol
Parameter
Conditions
Min
tHS-TRAIL
tEOT
Data Lane HS Exit
Transmitted time interval from the
start of tHS-TRAIL to the start of the
LP-11 state following a HS burst
60 +
4*UIINST
tHS-EXIT
Time that the transmitter drives LP-
11 following a HS burst.
100
tWAKEUP
Recovery Time from Ultra Low
Power State (ULPS)
1
www.ti.com
Typ
Max Units
ns
105 +
12*UIINST
ns
ns
ms
5.6 Recommended Timing for the Serial Control Bus (CCI/I2C)
Over supply and temperature ranges unless otherwise specified. ( Figure 7) (1)
Symbol
Parameter
Conditions
Min
fSCL
SCL Clock Frequency
Standard Mode
>0
Fast Mode
>0
tLOW
SCL Low Period
Standard Mode
4.7
Fast Mode
1.3
tHIGH
SCL High Period
Standard Mode
4.0
Fast Mode
0.6
tHD;STA
Hold time for a start or a
Standard Mode
4.0
repeated start condition
Fast Mode
0.6
tSU;STA
Set Up time for a start or a
Standard Mode
4.7
repeated start condition
Fast Mode
0.6
tHD;DAT
Data Hold Time
Standard Mode
0
Fast Mode
0
tSU;DAT
Data Set Up Time
Standard Mode
250
Fast Mode
100
tSU;STO
Set Up Time for STOP
Standard Mode
4.0
Condition
Fast Mode
0.6
tBUF
Bus Free Time
Standard Mode
4.7
Between STOP and START
Fast Mode
1.3
tr
SCL & SDA Rise Time
Standard Mode
Fast Mode
tf
SCL & SDA Fall Time
Standard Mode
Fast mode
Typ
Max
Units
100
kHz
400
kHz
us
us
us
us
us
us
us
us
3.45
us
0.9
us
ns
ns
us
us
us
us
1000
ns
300
ns
300
ns
300
ns