SNOSBG9B – JULY 1999 – REVISED JUNE 2015
Electrical Characteristics for V+ = +2.5 V and V− = −2.5 V (continued)
The following specifications apply for Mode 1, Q = 10 (R1 = R3 = 100 k, R2 = 10 k), V+ = +2.50 V and V− = −2.50 V unless
otherwise specified. All limits are TA = TJ = 25°C unless otherwise specified.
PARAMETER
TEST CONDITIONS
LMF100CCN
MIN
TYP
MAX
LMF100CIWM
MIN
TYP
MAX
UNIT
fCLK Clock frequency
5
15000
00
5
1500000 Hz
±0.2%
±0.2%
fCLK/f Clock to center frequency ratio
0
deviation
VPin12 = 5 V or 0
V, fCLK = 1 MHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
±1%
±1%
±1%
DQ
Q Error (MAX) (3)
Q
Q = 10, Mode 1,
VPin12 = 5 V or 0
V,
fCLK = 1 MHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±0.5%
±5%
±8%
±0.5%
±8%
0
0
HOBP Bandpass gain at f0
fCLK = 1 MHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±0.4
±0.5 dB
±0.5
0
0
HOLP DC Lowpass gain
R1 = R2 = 10 k,
fCLK = 250 kHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±0.2
±0.2 dB
±0.2
±5
±5
VOS1 DC Offset voltage(4)
fCLK = 250 kHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±15
±15
mV
±15
±20
±20
VOS2 DC Offset voltage(4)
SA/B = V+ Tested Limit(1) TMIN to TMAX
fCLK = 250 kHz
Design Limit(2) TMIN to TMAX
±10
±60
±60
±10
mV
±60
mV
SA/B = V–
Tested Limit(1)
Design Limit(2)
TMIN to TMAX
TMIN to TMAX
±50
±60
±10
±60
±10
VOS3 DC Offset voltage(4)
fCLK = 250 kHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±25
±30 mV
±30
Crosstalk (5)
A Side to B Side or B Side to A Side
–65
–65
dB
Output noise(6)
fCLK = 250 kHz
N
20 kHz Bandwidth BP
25
25
250
250
µV
100:1 Mode
LP
220
220
Clock feedthrough(7)
fCLK = 250 kHz 100:1 Mode
2
2
mV
(3) The accuracy of the Q value is a function of the center frequency (f0). This is illustrated in the curves under the heading Typical
Characteristics.
(4) Vos1, Vos2, and Vos3 refer to the internal offsets as discussed in the Application Information.
(5) Crosstalk between the internal filter sections is measured by applying a 1 VRMS 10-kHz signal to one bandpass filter section input and
grounding the input of the other bandpass filter section. The crosstalk is the ratio between the output of the grounded filter section and
the 1 VRMS input signal of the other section.
(6) In 50:1 mode the output noise is 3 dB higher.
(7) In 50:1 mode the clock feed through is 6 dB higher.
Copyright © 1999–2015, Texas Instruments Incorporated
Submit Documentation Feedback
7
Product Folder Links: LMF100