English
Language : 

LMF100_15 Datasheet, PDF (6/40 Pages) Texas Instruments – LMF100 Dual High-Performance Switched Capacitor Filters
LMF100
SNOSBG9B – JULY 1999 – REVISED JUNE 2015
www.ti.com
Electrical Characteristics for V+ = +5 V and V− = −5 V (continued)
The following specifications apply for Mode 1, Q = 10 (R1 = R3 = 100 k, R2 = 10 k), V+ = +5 V and V− = −5 V unless otherwise
specified. All limits are TA = TJ = 25°C unless otherwise specified.
PARAMETER
TEST CONDITIONS
LMF100CCN
MIN
TYP
MAX
LMF100CIWM
MIN
TYP
MAX
UNIT
±30
±30
VOS2 DC Offset voltage(4)
fCLK = 250 kHz
SA/B = V+
Tested Limit(1)
Design Limit(2)
TMIN to TMAX
TMIN to TMAX
±80
±80
±15
mV
±80
±15
SA/B = V–
Tested Limit(1)
Design Limit(2)
TMIN to TMAX
TMIN to TMAX
±70
±70
±15
mV
±70
±15
VOS3 DC Offset voltage(4)
fCLK = 250 kHz
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±40
±60 mV
±60
Crosstalk (5)
A Side to B Side or B Side to A Side
–60
–60
dB
Output noise(6)
fCLK = 250 kHz
N
20 kHz Bandwidth BP
40
40
320
320
µV
100:1 Mode
LP
300
300
Clock feedthrough(7)
fCLK = 250 kHz 100:1 Mode
6
4
−4.7
6
mV
4
−4.7
VOUT Minimum output voltage swing
RL = 5 k
(All Outputs)
Tested
Limit(1)
Design
Limit(2)
TMIN to TMAX
TMIN to TMAX
±3.8
±3.7
V
±3.7
RL = 3.5 k
(All Outputs)
3.9
−4.6
3.9
−4.6
GB Operational amplifier gain BW
W product
5
5
MHz
SR Operational amplifier slew rate
20
20
V/µs
Isc
Maximum output,
Source
Short circuit current(8) Sink
All Outputs
All Outputs
12
12
mA
45
45
mA
IIN
Input current on Pins: 4, 5, 6, 9,
10, 11, 12, 16, 17
Tested Limit(1)
Design Limit(2)
TMIN to TMAX
10
µA
10
(5) Crosstalk between the internal filter sections is measured by applying a 1 VRMS 10-kHz signal to one bandpass filter section input and
grounding the input of the other bandpass filter section. The crosstalk is the ratio between the output of the grounded filter section and
the 1 VRMS input signal of the other section.
(6) In 50:1 mode the output noise is 3 dB higher.
(7) In 50:1 mode the clock feed through is 6 dB higher.
(8) The short circuit source current is measured by forcing the output that is being tested to its maximum positive voltage swing and then
shorting that output to the negative supply. The short circuit sink current is measured by forcing the output that is being tested to its
maximum negative voltage swing and then shorting that output to the positive supply. These are the worst case conditions.
6.6 Electrical Characteristics for V+ = +2.5 V and V− = −2.5 V
The following specifications apply for Mode 1, Q = 10 (R1 = R3 = 100 k, R2 = 10 k), V+ = +2.50 V and V− = −2.50 V unless
otherwise specified. All limits are TA = TJ = 25°C unless otherwise specified.
PARAMETER
TEST CONDITIONS
LMF100CCN
MIN
TYP
MAX
LMF100CIWM
MIN
TYP
MAX
UNIT
8
8
Is
Maximum supply current
fCLK = 250 kHz,
No Input Signal
Tested
Limit (1)
Design
Limit (2)
TMIN to TMAX
12
12
12
mA
f0
Center frequency
0.1
50000
0.1
50000 Hz
(1) Tested limits are specified to Texas Instruments AOQL (Average Outgoing Quality Level).
(2) Design limits are specified to Texas Instruments AOQL (Average Outgoing Quality Level) but are not 100% tested.
6
Submit Documentation Feedback
Copyright © 1999–2015, Texas Instruments Incorporated
Product Folder Links: LMF100