English
Language : 

BQ24188_15 Datasheet, PDF (7/52 Pages) Texas Instruments – bq24188 2A, 30V, Host-Controlled Single-Input, Single Cell Switchmode Li-Ion Battery Charger with Power Path Management and USB-OTG Support
www.ti.com
bq24188
SLUSC44A – DECEMBER 2014 – REVISED MAY 2015
Electrical Characteristics (continued)
Circuit of Figure 7, VUVLO < VIN < VOVP AND VIN > VBAT+ VSLP, TJ = –40°C to 125°C and TJ = 25°C for typical values (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
BATTERY CHARGER
RON(BAT-SYS)
Internal battery charger
MOSFET on-resistance
Measured from BAT to SYS,
VBAT = 4.2V, High-Z mode
YFF
RGE
17
25
mΩ
32
47
Charge Voltage
Operating in voltage regulation, Programmable Range
3.5
4.44
V
RGE Package Voltage
Regulation Accuracy
TJ = 0°C to 50°C
-0.5%
0.5%
RGE Package Voltage
Regulation Accuracy
TJ = 0°C to 85°C
-0.7%
0.7%
VBATREG
YFF Package Voltage
Regulation Accuracy
RGE and YFF Package
Voltage Regulation Accuracy
TJ = 0°C to 85°C
TJ = 0°C to 125°C
-0.75%
-1.0%
0.75%
1.0%
YFF Package Voltage
Regulation Accuracy
TJ = 25°C
-29.2
28.1
YFF Package Voltage
Regulation Accuracy
TJ = 0°C to 85°C
-32.0
29.3
mV
YFF Package Voltage
Regulation Accuracy
TJ = 0°C to 125°C
-40.2
29.3
ICHARGE
VBATSHRT
VBATSHRT_HYS
Fast Charge Current Range
Fast Charge Current
Accuracy
Battery short circuit threshold
Hysteresis for VBATSHRT
Deglitch time for battery short
to fastcharge transition
VBATSHRT ≤ VBAT < VBAT(REG)
500 mA ≤ ICHARGE ≤ 1A
ICHARGE > 1000 mA
Battery voltage falling
VBAT rising or falling
500
2000
mA
–10%
10%
–5%
5%
1.9
2
2.1
V
100
mV
1
ms
IBATSHRT
Battery short circuit charge
current
VBAT < VBATSHRT
33.5
50
66.5
mA
ITERM
tDGL(TERM)
VRCH
tDGL(RCH)
VDET(SRC1)
Termination charge current
Deglitch time for charge
termination
Recharge threshold voltage
Deglitch time
Battery detection voltage
threshold
(TE = 1)
ITERM ≤ 50 mA
50 mA < ITERM < 200 mA
ITERM ≥ 200 mA
Both rising and falling, 2-mV over-drive,
tRISE, tFALL=100ns
Below VBATREG
VBAT falling below VRCH, tFALL=100ns
During current source (Turn IBATSHRT off)
–30%
–15%
–15%
32
100
120
32
30%
15%
10%
ms
150
mV
ms
VRCH
V
VDET(SRC2)
During current source (Turn IBATSHRT on)
VRCH
– 200mV
V
VDET(SNK)
IDETECT
Battery detection current
before charge done (sink
current)
During current sink
Termination enabled (TE = 1)
VBATSHRT
V
7
mA
tDETECT(SRC)
Battery detection time
(sourcing current)
Termination enabled (TE = 1)
2
s
tDETECT(SNK)
Battery detection time (sinking
current)
Termination enabled (TE = 1)
250
ms
Copyright © 2014–2015, Texas Instruments Incorporated
Product Folder Links: bq24188
Submit Documentation Feedback
7