BQ24188_15 Datasheet, PDF (16/52 Pages) Texas Instruments – bq24188 2A, 30V, Host-Controlled Single-Input, Single Cell Switchmode Li-Ion Battery Charger with Power Path Management and USB-OTG Support
bq24188
SLUSC44A – DECEMBER 2014 – REVISED MAY 2015
www.ti.com
Device Functional Modes (continued)
9.4.3.1.2 Input Voltage Based Dynamic Power Management (VIN-DPM)
During normal charging process, if the input power source is not able to support the programmed or default
charging current, the supply voltage deceases. Once the supply drops to VIN_DPM (default 4.2V), the charge
current limit is reduced to prevent the further drop of the supply. When the IC enters this mode, the charge
current is lower than the set value and the DPM_STATUS bit is set. This feature ensures IC compatibility with
adapters with different current capabilities without a hardware change. Figure 9 shows the VIN-DPM behavior to a
current limited source. In this figure the input source has a 2A current limit and the device is charging at 1A. A
2.5A load transient then occurs on VSYS causing the adapter to hit its current limit and collapse, while VSYS goes
from VSYSREG(LO) to VMINSYS. If the 2X timer is set, the safety timer is extended while VIN-DPM is active.
Additionally, termination is disabled.
VIN
(5V Offset)
Input voltage regulated to VIN_DPM
1V/div
IIN
VSYS
(3.6V Offset)
IBAT
Normal Charging (1A)
ISYS
Input current limit reduced to avoid crashing adapter
SYS enters supplement mode to ensure SYS load is supported
800us/div
Figure 9. bq24188 VIN-DPM
2A/div
500mV/div
2A/div SYS load removed,
normal charging
resumes
2A/div
9.4.3.1.3 Input Over-Voltage Protection
The built-in input over-voltage protection protects the bq24188 and downstream components connected to SYS
and/or BAT against damage from overvoltage on the input supply (Voltage from VIN to PGND). When VIN > VOVP,
the bq24188 turns off the PWM converter immediately. After the deglitch time tDGL(BUCK_OVP), an OVP fault is
determined to exist. During the OVP fault, the bq24188 turns the battery FET and BGATE on, sends a single
128μs pulse is sent on the STAT and INT outputs and the STATx and FAULT_x bits are updated in the I2C.
Once the OVP fault is removed, the STATx bits are cleared and the device returns to normal operation. The
FAULT_x bits are not cleared until they are read in the I2C after the OVP condition no longer exists.
The OVP threshold for the bq24188 is set to 14V to enable operation from 12V sources.
9.4.3.2 Charge Profile
When a valid input source is connected (VIN > VUVLO and VBAT + VSLP < VIN < VOVP), the CE bit in the control
register determines whether a charge cycle is initiated. By default, the bq24188 does not enable the charge
cycle when a valid input source is connected (CE = 1 by default). When the CE bit is 1 and a valid input source
is connected, the battery FET is turned off and the SYS output is regulated to VSYSREG(HI). A charge cycle is
initiated when the CE bit is written to a 0.
16
Submit Documentation Feedback
Product Folder Links: bq24188