SLUSC44A – DECEMBER 2014 – REVISED MAY 2015
8 Specifications
8.1 Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
IN
Terminal Voltage Range (with
respect to PGND)
BOOT, PMID
SW
BAT, BGATE, CD, INT, PSEL, SDA, SCL, STAT, TS
DRV, SYS
BOOT to SW
Output Current (Continuous)
SW
SYS, BAT (charging/ discharging)
Output Current (<20ms pulse,
<10% duty cycle)
BAT (discharging)
Input Current (Continuous)
Output Sink Current
STAT, INT
Operating free-air temperature range
Junction temperature, TJ
Storage Temperature, Tstg
VALUE
MIN
MAX
–1.3
30
–0.3
30
–0.7
20
–0.3
5.0
–0.3
5.5
–0.3
5
4.5
3.5
6
2.75
10
–40
85
–40
125
300
UNIT
V
V
A
A
A
mA
°C
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltage
values are with respect to the network ground terminal unless otherwise noted.
8.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2000
±500
UNIT
V
(1) Level listed above is the passing level per ANSI, ESDA, and JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows
safe manufacturing with a standard ESD control process.
(2) Level listed above is the passing level per EIA-JEDEC JESD22-C101. JEDEC document JEP157 states that 250-V CDM allows safe
manufacturing with a standard ESD control process.
8.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
IN voltage range
VIN
IN operating voltage range (bq24188)
IIN
ISW
IBAT, ISYS
Input current, IN input
Output Current from SW, DC
Charging
Discharging, using internal battery FET
TJ
Operating junction temperature range
MIN NOM MAX UNIT
4.2
28 (1)
V
4.2
13.2
2.5 A
2A
2
A
3
0
125 °C
(1) The inherent switching noise voltage spikes should not exceed the absolute maximum rating on either the BOOT or SW terminals. A
tight layout minimizes switching noise.
Copyright © 2014–2015, Texas Instruments Incorporated
Product Folder Links: bq24188