9.6.5 Battery Termination/Fast Charge Current Register (READ/WRITE)
Memory location: 04, Reset state: 0010 1010
Figure 23. Battery Termination/Fast Charge Current Register
B7(MSB)
B6
B5
B4
B3
B2
B1
B0(LSB)
0
0
1
0
1
0
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
BIT
FIELD
TYPE
DESCRIPTION
B7(MSB)
B6
B5
B4
B3
B2
B1
B0(LSB)
ICHRG4
ICHRG3
ICHRG2
ICHRG1
ICHRG0
ITERM2
ITERM1
ITERM0
R/W
Charge current 1600mA – (default 0)
R/W
Charge current: 800mA — (default 0)
R/W
Charge current: 400mA —(default 1)
R/W
Charge current: 200mA — (default 0)
R/W
Charge current: 100mA (default 1)
R/W
Termination current sense: 200mA (default 0)
R/W
Termination current sense voltage: 100mA (default 1)
R/W
Termination current sense voltage: 50mA (default 0)
ICHRG Bits (Charge Current Regulation Threshold setting)
Use ICHRG bits to set the charge current regulation threshold. The charge current is programmable from
500mA to 2A in 100mA steps. The default is 1A. The ICHARGE is calculated using the following equation:
indentICHARGE = 500 mA + ICHRGCODE × 100 mA
Any Operation above 2A is not specified.
ITERM Bits (Charge Current Termination Threshold setting)
Use ITERM bits to set the charge current termination threshold. The termination threshold is programmable
from 50mA to 300mA in 50mA steps. The default is 150mA. The ITERM is calculated using the following
equation:
indentITERM = 50 mA + ITERMCODE × 50 mA
Any setting programmed above 300mA selects the 300mA setting.