English
Language : 

OMAP5910JZZG2 Datasheet, PDF (159/171 Pages) Texas Instruments – This document has been reviewed for technical accuracy; the technical content is up-to-date as of the specified release date and includes the following changes
Electrical Specifications
5.17 HDQ/1-Wire Interface Timings
Table 5--34 and Table 5--35 assume testing over recommended operating conditions (see Figure 5--36
through Figure 5--39).
Table 5--34. HDQ/1-Wire Timing Requirements†
H1 tc
H2 tv
H3 tv
Cycle time, master read
Read one data valid after HDQ low
Read zero data hold after HDQ low
H4 tv Response time from HDQ slave device
W1 tc Cycle time, master read
W2 tv Read data valid after HDQ low (master sample window)
W3 tdis Recovery time after slave device inactive
† HDQ timing is OMAP5910 default. 1-Wire timing is selectable through software.
OMAP5910 base
frequency = 12 MHz
OMAP5910 base
frequency = 13 MHz
MIN MAX UNIT
190 250 μs
32
50 μs
80 145 μs
190 320 μs
190 303 μs
190
μs
12 13.6 μs
1
μs
Table 5--35. HDQ/1-Wire Switching Characteristics
PARAMETER
H5 tc Cycle time, master write
H6 td Write one data valid after HDQ low
H7 td Write zero data hold after HDQ low
OMAP5910 base
frequency = 12 MHz
OMAP5910 base
frequency = 13 MHz
H8 tw Pulse width, HDQ low for break pulse (reset)
H9 tw Pulse width, HDQ high for break pulse recovery
W4 tc Cycle time, master write
W5 td Write zero master inactive after HDQ low
W6 td Write one master inactive after HDQ low
W7 tdis Recovery time after master inactive
MIN MAX UNIT
190
μs
32
50 μs
100 145 μs
92 145 μs
190
μs
40
μs
190
μs
15
90 μs
1.1 1.4 μs
1
μs
August 2002 -- Revised August 2004