STE2004
6 ID-NUMBER
The STE2004 allows to program a Driver Identification Number (ID-Number). This make possible to easily
manage on one platform more than one LCD module with different configuration parameters.
Four are the device ID-Numbers programmable: 00111100, 00111101, 0011110 & 0011111. All have in
common the first 6 bits (001111). The two least significant bit could be set connecting the SA0 and SA1
inputs to a VSS or VDD1.
The driver ID-number can be read through all communication interfaces. The way to read-out the ID-Num-
ber changes according the interface selected. The readout protocol for each interface is described in the
Bus interfaces paragraph.
Table 10. STE2001/2-like instruction Set
Instruction
D/C R/W
Description
H=0 or H=1
B7 B6 B5 B4 B3 B2 B1 B0
Read Commnad 0 0 0 0 0 0 0 0 0 0
Read I2C Address or Status Byte
(with 3-Lines Serial & 4-lines SPI only)
Function Set
0 0 0 0 1 MX MY PD V H[0] Power Down Management; Entry
Mode;
Status Byte
ID Code
0 1 PD BSY 0 D E MX MY DO
0 1 0 0 1 1 1 1 ID1 ID0
(I2C interface only)
Write Data
H=0
1 0 D7 D6 D5 D4 D3 D2 D1 D0
Writes data to RAM
Memory Blank
Scroll
0 0 0 0 0 0 0 0 0 1 Starts Memory Blank Procedure
0 0 0 0 0 0 0 0 1 DIR Scrolls by one Row UP or DOWN
VLCD Range Setting 0 0 0 0 0 0 0 1 0 PRS VLDC programming range selection
[0]
Display Control 0 0 0 0 0 0 1 D 0 E
Select Display Configuration
Set CP Factor
0 0 0 0 0 1 0 S2 S1 S0 Charge Pump Multiplication
factor
Set RAM Y
Set RAM X
0 0 0 1 0 0 Y3 Y2 Y1 Y0 Set Horizontal (Y) RAM Address
0 0 1 X6 X5 X4 X3 X2 X1 X0 Set Vertical (X) RAM Address
H=1
Checker Board
0 0 0 0 0 0 0 0 0 1 Starts Checker Board Procedure
Duty
TC Select
Data Order
0 0 0 0 0 0 0 0 1 MUX
Selects Duty factor
0 0 0 0 0 0 0 1 TC1 TC0 Set Temperature Coefficient for VLDC
0 0 0 0 0 0 1 DO 0 0
Bias Ratios
0 0 0 0 0 1 0 BS2 BS1 BS0
Set desired Bias Ratios
Reserved
00 0 1XXXXXX
Not to be used
Set VOP
0 0 1 OP6 OP5 OP4 OP3 OP2 OP1 OP0 VOP register Write instruction
40/66