LPS35HW
FIFO
4.6
Bypass-to-Stream mode
In Bypass-to-Stream mode (FIFO_CTRL(FMODE2:0) = '100'), data measurement storage
inside FIFO operates in Stream mode when INT_SOURCE(IA) is equal to '1',otherwise
FIFO content is reset (Bypass mode). An interrupt generator can be set to the desired
configuration through INTERRUPT_CFG(0Bh).
The INTERRUPT_CFG(LIR) bit should be set to '1' in order to have latched interrupt.
Figure 11: Bypass-to-Stream mode
DocID029129 Rev 1
19/48