English
Language : 

M16C5L_15 Datasheet, PDF (92/116 Pages) Renesas Technology Corp – RENESAS MCU
M16C/5L Group, M16C/56 Group
5. Electrical Characteristics
K-Version
5.4.5 Voltage Detector and Power Supply Circuit Electrical Characteristics
Table 5.52 Voltage Detector 0 Electrical Characteristics
The measurement condition is VCC = 3.0 to 5.5 V, Topr = -40°C to 125°C, unless otherwise specified.
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
Vdet0
td(E-A)
Voltage detection level Vdet0
Waiting time until voltage detector operation
starts (1)
When VCC is falling.
VCC = 3.0 to 5.0 V
2.70 2.85 3.00 V
100 μs
Note:
1. Necessary time until the voltage detector operates when setting to 1 again after setting the VC25 bit in the VCR2
register to 0.
Table 5.53 Voltage Detector 2 Electrical Characteristics
The measurement condition is VCC = 3.0 to 5.5 V, Topr = -40°C to 125°C, unless otherwise specified.
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
Vdet2_0
Vdet2_1
Vdet2_2
Vdet2_3
Vdet2_4
Vdet2_5
Vdet2_6
Vdet2_7
-
td(E-A)
Voltage detection level Vdet2_0
Voltage detection level Vdet2_1
Voltage detection level Vdet2_2
Voltage detection level Vdet2_3
Voltage detection level Vdet2_4
When VCC is falling
Voltage detection level Vdet2_5
Voltage detection level Vdet2_6
Voltage detection level Vdet2_7
Hysteresis width at the rising of VCC in voltage
detector 2
Waiting time until voltage detector operation starts (1) VCC = 3.0 to 5.0 V
3.21
V
3.36
V
3.51
V
3.66
V
3.51 3.81 4.11 V
3.96
V
4.10
V
4.25
V
0.15
V
100 μs
Note:
1. Necessary time until the voltage detector operates after setting to 1 again after setting the VC27 bit in the VCR2
register to 0.
R01DS0035EJ0110 Rev.1.10
Sep 01, 2011
Page 92 of 112