English
Language : 

M16C5LD Datasheet, PDF (80/85 Pages) Renesas Technology Corp – RENESAS MCU
M16C/5LD Group, M16C/56D Group
5. Electrical Characteristics
Timing Requirements
(VCC = 3 V, VSS = 0 V, at Topr = −40 to 85°C unless otherwise specified)
VCC = 3 V
Table 5.36 Timer A Input (Two-phase Pulse Input in Event Counter Mode)
Symbol
tc(TA)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
Parameter
TAiIN Input Cycle Time
TAiOUT Input Setup Time
TAiIN Input Setup Time
Standard
Unit
Min.
Max.
2
μs
500
ns
500
ns
Two-phase pulse input in event counter mode
tc(TA)
TAiIN input
TAiOUT input
tsu(TAIN-TAOUT)
tsu(TAIN-TAOUT)
tsu(TAOUT-TAIN)
tsu(TAOUT-TAIN)
Figure 5.17 Timer A Input (Two-Phase Pulse Input in Event Counter Mode)
REJ03B0307-0110 Rev.1.10 Dec 01, 2009
Page 80 of 83