5. Electrical Characteristics
Table 5.10 Power-On Reset Circuit
The measurement condition is Topr = -40 to 85°C, unless otherwise specified.
Symbol
Parameter
Condition
Standard
Unit
Min. Typ. Max.
trth
External power VCC rise gradient
tfth
External power VCC fall gradient
2.0
50000 mV/ms
50000 mV/ms
Vpor
tw(por)
Voltage at which power-on reset enabled (1)
Hold time at which power-on reset enabled
0.1
V
1.0
ms
Note:
1. To use the power-on reset function, enable voltage monitor 0 reset by setting the LVDAS bit in the OFS1 address
to 0.
Vdet0
t rth
External Power VCC
Vpor
tw(por)
Internal
reset signal
t fth
1
× 128
fOCO-S
Vdet0
t rth
1
× 128
fOCO-S
Figure 5.4 Power-On Reset Circuit Electrical Characteristics
Table 5.11 Power Supply Circuit Timing Characteristics
Symbol
Parameter
Measuring Condition
td(P-R)
Time for Internal Power Supply Stabilization VCC = 3.0 V to 5.5V
During Powering-On
td(R-S)
td(W-S)
STOP Release Time
Low Power Mode Wait Mode Release Time
Note:
1. When VCC = 5 V.
Standard
Unit
Min. Typ. Max.
5
ms
300 μs
150 μs