English
Language : 

M16C65C_15 Datasheet, PDF (56/112 Pages) Renesas Technology Corp – RENESAS MCU
M16C/65C Group
5. Electrical Characteristics
5.1.5 Flash Memory Electrical Characteristics
Table 5.8 CPU Clock When Operating Flash Memory (f(BCLK))
VCC1 = 2.7 to 5.5 V, Topr = -20°C to 85°C/-40°C to 85°C unless otherwise specified.
Symbol
Parameter
Conditions
Standard
Unit
Min.
Typ.
Max.
-
CPU rewrite mode
10 (1) MHz
f(SLOW_R) Slow read mode
5 (3) MHz
-
Low current consumption read mode
fC(32.768) 35
kHz
-
Data flash read
2.7 V ≤ VCC1 ≤ 3.0 V
3.0 V < VCC1 ≤ 5.5 V
16 (2)
20 (2)
MHz
MHz
Notes:
1. Set the PM17 bit in the PM1 register to 1 (one wait).
2. When the frequency is over this value, set the FMR17 bit in the FMR1 register to 0 (one wait) or the PM17 bit in
the PM1 register to 1 (one wait)
3. Set the PM17 bit in the PM1 register to 1 (one wait). When using 125 kHz on-chip oscillator clock or sub clock as
the CPU clock source, a wait is not necessary.
Table 5.9 Flash Memory (Program ROM 1, 2) Electrical Characteristics
VCC1 = 2.7 to 5.5 V at Topr = 0°C to 60°C (option: -40°C to 85°C), unless otherwise specified.
Symbol
Parameter
Conditions
Standard
Unit
Min. Typ.
Max.
-
Program and erase cycles (1), (3), (4) VCC1 = 3.3 V, Topr = 25°C
1,000 (2)
times
-
2 word program time
VCC1 = 3.3 V, Topr = 25°C
150
4000
μs
-
Lock bit program time
VCC1 = 3.3 V, Topr = 25°C
70
3000 μs
-
Block erase time
VCC1 = 3.3 V, Topr = 25°C
0.2
3.0
s
td(SR-SUS)
Time delay from suspend request
until suspend
-
Interval from erase start/restart
until following suspend request
5 + -------3-------- ms
f(BCLK)
0
μs
-
Suspend interval necessary for
auto-erasure to complete (7)
-
Time from suspend until erase
restart
-
Program, erase voltage
20
ms
30 + -------1-------- μs
f(BCLK)
2.7
5.5
V
-
Read voltage
Topr= -20°C to 85°C/-40°C to 85°C 2.7
-
Program, erase temperature
0
5.5
V
60
°C
tPS
Flash memory circuit stabilization wait time
50
μs
-
Data hold time (6)
Ambient temperature = 55°C
20
year
Notes:
1. Definition of program and erase cycles:
The program and erase cycles refer to the number of per-block erasures. If the program and erase cycles are n
(n = 1,000), each block can be erased n times. For example, if a block is erased after writing 2 word data 16,384
times, each to a different address, this counts as one program and erase cycles. Data cannot be written to the
same address more than once without erasing the block (rewrite prohibited).
2. Cycles to guarantee all electrical characteristics after program and erase. (1 to Min. value can be guaranteed).
3. In a system that executes multiple programming operations, the actual erasure count can be reduced by writing
to sequential addresses in turn so that as much of the block as possible is used up before performing an erase
operation. It is advisable to retain data on the erasure cycles of each block and limit the number of erase
operations to a certain number.
4. If an error occurs during block erase, attempt to execute the clear status register command, then execute the
block erase command at least three times until the erase error does not occur.
5. Customers desiring program/erase failure rate information should contact a Renesas Electronics sales office.
6. The data hold time includes time that the power supply is off or the clock is not supplied.
7. After an erase start or erase restart, if an interval of at least 20 ms is not set before the next suspend request, the
erase sequence cannot be completed.
R01DS0015EJ0110 Rev.1.10
Jul 31, 2012
Page 56 of 109