24.11.MOUNTING ORIENTATIONS
Mounting orientations other than all terminals on the bottom require a reduction in continuous output power or a
limitation in the maximum allowed ambient temperature. The amount of reduction influences the lifetime expectancy
of the power supply. Therefore, two different derating curves for continuous operation can be found below:
Curve A1
Curve A2
Recommended output current.
Max allowed output current (results in approximately half the lifetime expectancy of A1).
Fig. 24-4
Mounting
Orientation A
(Standard
orientation)
OUTPUT
Power
Supply
INPUT
Output Current
6A
5
4
3
2
1
0
10
Ambient Temperature
20 30 40 50
A1
60°C
Fig. 24-5
Mounting
Orientation B
(Upside down)
Output Current
6A
5
A2
4
A1
3
2
1
0
10
Ambient Temperature
20 30 40 50
60°C
Fig. 24-6
Mounting
Orientation C
(Table-top
mounting)
Output Current
6A
5
4
A2
3
A1
2
1
0
10
Ambient Temperature
20 30 40 50
60°C
Fig. 24-7
Mounting
Orientation D
(Horizontal cw)
Output Current
6A
5
4
A2
3
A1
2
1
0
10
Ambient Temperature
20 30 40 50
60°C
Fig. 24-8
Mounting
Orientation E
(Horizontal ccw)
Output Current
6A
5
4
A2
3
A1
2
1
0
10
Ambient Temperature
20 30 40 50
60°C
Aug. 2017 / Rev. 0.1 DS-CP5.241-EN
All parameters are typical values specified at 24V, 5A output, 230Vac input, 25°C ambient and
after a 5 minutes run-in time unless otherwise noted.