English
Language : 

BUK112-50GL Datasheet, PDF (4/16 Pages) NXP Semiconductors – PowerMOS transistor Logic level TOPFET
Philips Semiconductors
PowerMOS transistor
Logic level TOPFET
Product specification
BUK112-50GL
PROTECTION SUPPLY CHARACTERISTICS
Tmb = 25 ˚C unless otherwise specified
SYMBOL PARAMETER
CONDITIONS
Normal operation or
protection latched
IPS, IPSL
Supply current
VPS = 4.5 V
-40˚C ≤ Tmb ≤ 150˚C
V(CL)PS
Clamping voltage
IP = 1.5 mA
Overload protection latched
VPSR
t pr
Reset voltage
Reset time
VPS = 0 V
-40˚C ≤ Tmb ≤ 150˚C
-40˚C ≤ Tmb ≤ 150˚C
MIN. TYP. MAX. UNIT
-
330 400 µA
-
-
450 µA
6
7.1
-
V
-
2.1
-
V
1.5
-
3
V
-
25
-
µs
-
-
150 µs
OPEN CIRCUIT LOAD DETECTION CHARACTERISTICS
An open circuit load condition can be detected while the TOPFET is in the off-state.
-40˚C ≤ Tmb ≤ 150˚C; VPS = 5 V; VDS = 13 V unless otherwise specified
SYMBOL PARAMETER
CONDITIONS
MIN.
IDSP
Off-state drain current1
VIS = 0 V
0.5
IDSF
Off-state drain threshold current VIS = 0 V; IF = 100 µA
0.4
VISF
Input threshold voltage2
IF = 100 µA; ID = 100 µA;
-
Tmb = 25 ˚C
TYP.
1.4
1.1
1.2
MAX. UNIT
2 mA
-
mA
-
V
TRUTH TABLE
For normal, open-circuit load and overload conditions or inadequate protection supply voltage.
CONDITION
PROTECTION
INPUT
FLAG
Normal on-state
1
1
0
OUTPUT
1
Normal off-state
1
0
0
0
Open circuit load
1
1
0
1
Open circuit load
1
0
1
0
Short circuit load
1
1
1
0
Over temperature
1
X
1
0
Low protection supply voltage
0
1
1
1
Low protection supply voltage
0
0
1
0
For protection ‘0’ equals low, ‘1’ equals high.
For input ‘0’ equals low, ‘1’ equals high, ‘X’ equals don’t care.
For flag ‘0’ equals low, ‘1’ equals open or high.
For output switch ‘0’ equals off, ‘1’ equals on.
1 The drain source current which flows when the protection supply is high and the input is low.
2 For open circuit load indication, VIS must be less than VISF.
September 1996
4