English
Language : 

SDA9400 Datasheet, PDF (82/94 Pages) Micronas – Scan Rate Converter using Embedded DRAM Technology Units
SDA 9400
Bit
D7...D3
D2...D1
D0
Name
NMLINE
SVALLI
x
Subaddress 28
Function
Line for noise measurement (only valid for NMALG=1) [NMLINE = 4]
Sensitivity of line difference in the motion detection for scan rate
conversion:
11: factor 32 (minimum)
10: factor 16
01: factor 8
00: factor 4 (maximum)
x
Bit
D7...D2
D1...D0
Name
THLI2
THLI1(4...3)
Subaddress 29
Function
Threshold 2 of line difference in the motion detection for scan rate
conversion [THLI2 = 12]
Threshold 1 (Bit 4 and Bit 3) of line difference in the motion detection for
scan rate conversion [THLI14...3 = 1]
Bit
D7...D5
D4...D1
D0
Name
THLI1(2...0)
THLI0
THFI3(4)
Subaddress 2A
Function
Threshold 1 (Bit 2, Bit 1 and Bit 0) of line difference in the motion
detection for scan rate conversion [THLI12...0 = 0]
Threshold 0 of line difference in the motion detection for scan rate
conversion [THLI0 = 4]
Threshold 3 (Bit 4) of field difference in the motion detection for scan rate
conversion [THFI34 = 1]
Bit
D7...D4
D3...D0
Name
THFI3(3...0)
THFI2(4...1)
Subaddress 2B
Function
Threshold 3 (Bit 3, Bit 2,Bit 1and Bit 0) of field difference in the motion
detection for scan rate conversion [THFI33...0 = 12]
Threshold 2 (Bit 4, Bit3, Bit 2 and Bit 1) of field difference in the motion
detection for scan rate conversion [THFI24...1 = 9]
Micronas
82
Preliminary Data Sheet