MAX11014_08 Datasheet, PDF (63/70 Pages) Maxim Integrated Products – Automatic RF MESFET Amplifier Drain-Current Controllers
Automatic RF MESFET Amplifier
Drain-Current Controllers
KLUT2BASE
0xC7
KLUT1BASE = 0011 0011 0011 (819d)
0xC6
TLUT2BASE
0xC5
TLUT1BASE
0xC4
KLUT2CNFG
0xC3
KLUT1CNFG = 0 0100 1xxx 1000
0xC2
TLUT2CNFG
0xC1
T LUT1CNFG
0xC0
1.7499V
1.5936V
1.4374V
1.2811V
1.1249V
0.9686V
0.8124V
0.6561V
KLUT1 BASE = 0.4999V
KLUT1 VALUE 9 = UNUSED
KLUT1 VALUE 8
0x68
KLUT1 VALUE 7
0x67
KLUT1 VALUE 6
0x66
KLUT1 VALUE 5
0x65
KLUT1 VALUE 4
0x64
KLUT1 VALUE 3
0x63
KLUT1 VALUE 2
0x62
KLUT1 VALUE 1
0x61
KLUT1 VALUE 0
0x60
Figure 30. KLUT Example
The KLUT data is stored in straight binary format.
Figure 30 details a channel 1 KLUT example with nine
entries, a range of 0.5V to 1.7V, and a step size of 256.
Assuming VREFDAC = +2.5V, the base value (819d) is
determined by the following equation:
0.5V x 4096 = 819d
2.5V
Internally Timed Acquisitions
and Conversions
Clock Mode 00
In clock mode 00, power-up, acquisition, conversion,
and power-down are all initiated by writing to the ADC
conversion register and performed automatically using
the internal oscillator. This is the default clock mode.
With ADCMON set to 1, the ADC sets the BUSY output
high, powers up, scans all requested channels, stores
the results in the FIFO, and then powers down. After the
scan is complete, the BUSY output is pulled low and
the results are available in the FIFO.
______________________________________________________________________________________ 63