English
Language : 

MAX11014_08 Datasheet, PDF (32/70 Pages) Maxim Integrated Products – Automatic RF MESFET Amplifier Drain-Current Controllers
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 2. Register Listing (see Appendix: Startup Code Example for sample startup
sequence)
REGISTER DESCRIPTION
ADC Conversion
ALARM Flag Register
Channel 1 DAC Input
Channel 1 DAC Input and Output
Channel 1 High GATE Voltage ALARM Threshold
Channel 1 High Sense Voltage ALARM Threshold
Channel 1 High Temperature ALARM Threshold
Channel 1 K Parameter
Channel 1 Low GATE Voltage ALARM Threshold
Channel 1 Low Sense Voltage ALARM Threshold
Channel 1 Low Temperature ALARM Threshold
Channel 1 VSET
Channel 2 DAC Input
Channel 2 DAC Input and Output
Channel 2 High GATE Voltage ALARM Threshold
Channel 2 High Sense Voltage ALARM Threshold
Channel 2 High Temperature ALARM Threshold
Channel 2 K Parameter
Channel 2 Low GATE Voltage ALARM Threshold
Channel 2 Low Sense Voltage ALARM Threshold
Channel 2 Low Temperature ALARM Threshold
Channel 2 VSET
First-In First-Out Memory
Flag Register
Hardware ALARM Configuration
Hardware Configuration
LUT Address
LUT Data
PGA Calibration Control
Shutdown
Software ALARM Configuration
Software Clear
Software Configuration
Software Load DAC
MNEMONIC
ADCCON
ALMFLAG
IPDAC1
THRUDAC1
VH1
IH1
TH1
USRK1
VL1
IL1
TL1
VSET1
IPDAC2
THRUDAC2
VH2
IH2
TH2
USRK2
VL2
IL2
TL2
VSET2
FIFO
FLAG
ALMHCFG
HCFG
LUTADD
LUTDAT
PGACAL
SHUT
ALMSCFG
SCLR
SCFG
LDAC
HEX CODE
WRITE
62
—
48
4A
28
24
20
44
2A
26
22
40
4C
4E
34
30
2C
46
36
32
2E
42
—
—
3C
38
7A
7C
5E
64
3E
74
3A
66
READ
—
F8
—
—
A8
A4
A0
—
AA
A6
A2
—
—
—
B4
B0
AC
—
B6
B2
AE
—
80
F6
BC
B8
—
FC
—
—
BE
—
BA
—
Register Descriptions
The MAX11014/MAX11015 communicate between the
internal registers and external bus lines through the serial
interface. Table 1 details the command bits (C7–C0) and
the data bits (D15–D0) of the serial input word. Table 2
details the command byte and the subsequent register
accessed. Tables 3–27 detail the various read and write
internal registers and their power-on reset states.
On power-up, the MAX11014/MAX11015 are in full
power-down mode (see the SHUT (Write) section). To
32 ______________________________________________________________________________________