English
Language : 

MAX11014_08 Datasheet, PDF (38/70 Pages) Maxim Integrated Products – Automatic RF MESFET Amplifier Drain-Current Controllers
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 11. SCFG (Read/Write)
BIT NAME
X
LDAC2
T2COMP1
T2COMP0
KSRC2-2
KSRC2-1
KSRC2-0
LDAC1
T1COMP1
T1COMP0
KSRC1-2
KSRC1-1
KSRC1-0
DATA BIT
D15–D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
RESET STATE
X
0
0
0
0
0
0
0
0
0
0
0
0
FUNCTION
Don’t care.
Channel 2 load DAC. Set to 1 to load the new value of VDAC2(CODE),
upon completion of a VDAC2(CODE) calculation, into both the channel 2
DAC input and output registers. When set to 1, BUSY pulses high after a
new VDAC2 output is calculated. Set to 0 to load the new value of
VDAC2(CODE), upon completion of a VDAC2(CODE) calculation, to only the
channel 2 DAC input register. When set to 0, set the DACCH2 bit high in
the software load DAC register to transfer the VDAC(CODE) calculation
value from the DAC input register to the DAC output.
Channel 2 temperature LUT control bits.
Channel 2 KLUT control bits.
Channel 1 load DAC. Set to 1 to load the new value of VDAC1, upon
completion of a VDAC1(CODE) calculation, into both the channel 1 DAC
input and output registers. When set to 1, BUSY pulses high after a new
VDAC1 output is calculated. Set to 0 to load the new value of VDAC1,
upon completion of a VDAC1(CODE) calculation, to only the channel 1
DAC input register. When set to 0, set the DACCH1 bit high in the
software load DAC register to transfer the VDAC(CODE) calculation value
from the DAC input register to the DAC output.
Channel 1 temperature LUT control bits.
Channel 1 KLUT control bits.
38 ______________________________________________________________________________________