English
Language : 

71M6543F Datasheet, PDF (107/157 Pages) Maxim Integrated Products – Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
Name
EX_XFER
EX_RTC1S
EX_RTC1M
EX_RTCT
EX_SPI
EX_EEX
EX_XPULSE
EX_YPULSE
EX_WPULSE
EX_VPULSE
EW_DIO4
EW_DIO52
EW_DIO55
EW_PB
EW_RX
FIR_LEN[1:0]
71M6543F/H and 71M6543G/GH Data Sheet
Location Rst Wk Dir
2700[0]
2700[1]
2700[2]
2700[3]
2701[7]
2700[7]
2700[6]
2700[5]
2701[6]
2701[5]
0 0 R/W
28B3[2] 0 – R/W
28B3[1] 0 – R/W
28B3[0] 0 – R/W
28B3[3] 0 – R/W
28B3[4] 0 – R/W
210C[2:1] 0 0 R/W
Description
Interrupt enable bits. These bits enable the XFER_BUSY, the RTC_1SEC, etc. The
bits are set by hardware and cannot be set by writing a 1. The bits are reset by writing
0. Note that if one of these interrupts is to enabled, its corresponding 8051 EX enable
bit must also be set. See 2.4.9 Interrupts, for details.
Connects SEGDIO4 to the WAKE logic and permits SEGDIO4 rising to wake the part.
This bit has no effect unless DIO4 is configured as a digital input.
Connects SEGDIO52 to the WAKE logic and permits SEGDIO52 rising to wake the part.
This bit has no effect unless SEGDIO52 is configured as a digital input.
Connects SEGDIO55 to the WAKE logic and permits the SEGDIO55 rising edge to
awaken the part. This bit has no effect unless SEGDIO55 is configured as a digital
input.
Connects PB to the WAKE logic and permits the PB rising edge to awaken the part. PB
is always configured as an input.
Connects RX to the WAKE logic and permits the RX rising edge to awaken the part.
See the WAKE description in 3.4 Wake on Timer for de-bounce issues.
Determines the number of ADC cycles in the ADC decimation FIR filter.
PLL_FAST = 1:
FIR_LEN[1:0] ADC Cycles
00
141
01
288
10
384
PLL_FAST = 0:
FIR_LEN[1:0] ADC Cycles
00
135
01
276
10
Not Allowed
The ADC LSB size and full-scale values depend on the FIR_LEN[1:0] setting. Refer to
Table 83 on page 126 and Table 105 on page 144 for details.
v1.2
© 2008–2011 Teridian Semiconductor Corporation
107