B. Rotary Power Unit
1. Disconnect the electrical power and air supply from the base machine.
2. Push the gripper slide down, or facing the power unit, push the upper part of the inserter clamp to the
left.
Manually Opening Inserter Clamp
Straight Power Unit
Front of Power Unit
Inserter
Assembly
Push
Push
Clamp Actuating
Arm
Rotary Power Unit
Push
Gripper Slide
Push Inserter
Clamp Here
Squeeze Together
Push Gripper Slide Down or
Push Inserter Assembly Left
Figure 9
4. REMOVAL
4.1. Removing Power Unit from Machine
1. Disconnect the electrical power and air supply from the base machine.
DANGER
To avoid personal injury, ALWAYS DISCONNECT the electrical power and air supply from the base machine before
removing the power unit from the machine.
2. If the terminal strip is in the tool set:
a. Cut the carrier strip at the front of the tool set where it enters the scrap tube. Then remove the
scrap from the scrap tube.
b. From the rear of the machine, rotate the drag release lever forward until it latches, to release the
drag and disengage the feed finger. See Figure 8.
c. Press the rear of the anti–backup finger to disengage the finger.
d. Pull the terminal strip from the rear of the tool set.
e. Return drag lever to its applied (run) position.
NOTE
i
It is recommended that a short section of the terminal strip remain in the tool set during removal and when being
placed into storage to help identify the tool set.
Rev A