English
Language : 

TLE8110EE Datasheet, PDF (69/72 Pages) Infineon Technologies AG – Smart Multichannel Low Side Switch with Parallel Control and SPI Interface
Field
Bits
DCCx
2:0
Type
R/W
FLEX
Smart Multi-Channel Switch
Control of the device
Description
DCCx - Diagnosis Current Control
DCC18 switching ON/OFF diagnosis current of CH1-8
DCC9 switching ON/OFF diagnosis current of CH9
DCC10 switching ON/OFF diagnosis current of CH10
0 OFF-State Diagnosis (Detection of open load and short to GND)
of CHx is switched OFF. ON state diagnosis (over current and
over temperature detection) is still active.
Diagnosis Current is switched OFF.
1 OFF-State (Detection of open load and short to GND) and ON-
State (over current and over temperature detection) Diagnosis
of CHx switched ON,
Diagnosis Current is switched ON
default DCC = 1
Data Sheet
69