English
Language : 

TLE8110EE Datasheet, PDF (64/72 Pages) Infineon Technologies AG – Smart Multichannel Low Side Switch with Parallel Control and SPI Interface
FLEX
Smart Multi-Channel Switch
Control of the device
S_SO
SPI_Serial Output
CS 15 14 13
TOR PAR 0
0
12 11 10 9
8
7
6
5
4
3
2
1
0
1
DRx DRx DRx DRx DRx DRx DRx DRx DRx DRx DRx DRx
[1]x [0]x [1]x [0]x [1]x [0]x [1]x [0]x [1]x [0]x [1]x [0]x
Field
-
Bits
-
Type
-
Description
DRx Contents
0 no Diagnosis Error
1 Diagnosis Error
12.3.2.3 DMSx/OPSx - Diagnosis Mode Set / Output Pin Set Commands
Protocol
Each Cycle where a serial data or command frame is sent to the Serial Input [SI] of the SPI interface, a data frame
is returned immediately by the Serial Output [SO]. The content of the SO frame is dependent of the previous
command which has been sent to SI and the content of the actual content of SI: The first Byte send by S_SI
controls the content of the second byte actual returned by S_SO. The second Byte send by S_SI controls the first
byte in S_SO of the next frame. (see Figure 37)
DMSx OPSx
Upper
TOR Byte
DO
Upper
Byte
Lower
Byte
TOR OPF
Lower
Byte
Figure 37 Data Transfer in Diagnosis and Compact Control
Upper
Byte
Lower
Byte
Upper
TOR Byte
Lower
Byte
SPI_Protocol_Short_Mode.vsd
S_SI
SPI_Serial Input
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Diagnosis Mode Set DMS[4:0]
Output Pin Set OPS[7:0]
-
serial mode selected
parallel or serial mode
0
001-
-
-
-
CH10: CH9: CH8: CH7: CH10: CH9: CH8: CH7:
1:ON 1:ON 1:ON 1:ON 0 = 0 = 0 = 0 =
0:OFF 0:OFF 0:OFF 0:OFF serial serial serial serial
1= 1= 1= 1=
par. par. par. par.
Data Sheet
64