Diagnosis
8.2
Electrical Characteristics Diagnosis
Electrical Characteristics: OFF State Diagnosis
3V < VCC < 5.5V; 4.5V < VDD < 5.5V; Vbatt = 13.5V, Tj = -40 °C to +150 °C, all voltages with respect to ground,
positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Open Load Diagnosis
8.2.1 Open load detection threshold
VDSol
2.00 2.60 3.20 V
-
voltage
8.2.2 Output pull-down diagnosis current IDpd
per channel (low level)
50
90
150
µA
VDS = 13.5 V
8.2.3
Open Load Diagnosis Delay Time td
(all channels)
100 -
220 µs
DEVS.DBT1=0
DEVS.DBT2=1
or 0
8.2.4
a)
b)
Channel 7-10:
td
Open Load Diagnosis Delay Time
“Diagnosis Blind Time” see chapter
“Control of the device”
Figure 17, Figure 18
1.65 2.5
3.3
5
3.45 ms
7.3
ms
DEVS.DBT1=1
DEVS.DBT2=0
DEVS.DBT1=1
DEVS.DBT2=1
Short to GND Diagnosis
8.2.5 Short to ground detection threshold VDSsg
1.00 1.50 2.00 V
-
voltage
8.2.6 Output diagnosis current for short IDsg
to ground per channel (low level)
-150 -100 -50
µA
VDS = 0V
8.2.7 Short to GND Diagnosis Delay
td
Time
100 -
220 µs
DEVS.DBT1=0
DEVS.DBT2=1
or 0
8.2.8
a)
b)
Channel 7-10:
td
Short to GND Diagnosis Delay
Time. “Diagnosis Blind Time” see
chapter “Control of the device”,
Figure 17, Figure 18
1.65 2.5
3.3
5
3.45 ms
7.3
ms
DEVS.DBT1=1
DEVS.DBT2=0
DEVS.DBT1=1
DEVS.DBT2=1
Data Sheet
32