12.3.2.1 DRx - Diagnosis Registers Contents
DRA[1:0]x / DRB[1:0]x
Diagnosis Register CHx Bank A and Bank B
FLEX
Smart Multi-Channel Switch
Control of the device
Reset Value: 0000 0000 0000B = 000h
11
DRA[1]6
10
DRA[0]6
9
8
7
6
5
4
3
2
1
0
DRA[1]5 DRA[0]5 DRA[1]4 DRA[0]4 DRA[1]3 DRA[0]3 DRA[1]2 DRA[0]2 DRA[1]1 DRA[0]1
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0 DRB[1]10 DRB[0]10 DRB[1]9 DRB[0]9 DRB[1]8 DRB[0]8 DRB[1]7 DRB[0]7
Field
Bits
DRA[1:0]x / 1:0
DRB[1:0]x
Type
R
Description
DRA[1:0]x / DRB[1:0]x
DRn[1]x/DRn[0]x = 11 no Error
DRn[1]x/DRn[0]x = 10 Over Load, Shorted Load, Over temperature in
ON-Mode
DRn[1]x/DRn[0]x = 01 Open Load in OFF-Mode
DRn[1]x/DRn[0]x = 00 Short to GND in OFF-Mode
default DRx[1:0] = 11B
A new error on the same channel will overwrite older information.
The diagnosis information which is returned by SO is latched when
CS makes a High-to-Low transistion of the frame which sends
out the register.
12.3.2.2 DRx - Return on DRx Commands
x_DRx
W
x_DRx
TOR
dept. of
previous R/W
R/W
xxxx
TOR
DRx
Figure 36 SPI Feedback on x_DRx commands
R/W
xxxx
TOR
xxxx
SPI_Protocol_x_DRx.vsd
Data Sheet
63
Rev. 1.0, 2009-06-15