English
Language : 

HYB18L128160BF Datasheet, PDF (50/53 Pages) Infineon Technologies AG – DRAMs for Mobile Applications
HY[B/E]18L128160B[C/F]-7.5
128-Mbit Mobile-RAM
Electrical Characteristics
3.3
Operating Currents
Table 21 Maximum Operating Currents1)
Parameter & Test Conditions
Symbol Values
Unit
- 7.5
Operating current:
one bank: active / read / precharge, BL = 1, tRC = tRCmin
Precharge power-down standby current:
all banks idle, CS ≥ VIHmin, CKE ≤ VILmax,
inputs changing once every two clock cycles
IDD1
60
mA
IDD2P
0.5
mA
Precharge power-down standby current with clock stop:
all banks idle, CS ≥ VIHmin, CKE ≤ VILmax, all inputs stable
Precharge non power-down standby current:
all banks idle, CS ≥ VIHmin, CKE ≥ VIHmin,
inputs changing once every two clock cycles
IDD2PS
0.35
mA
IDD2N
13
mA
Precharge non power-down standby current with clock stop:
IDD2NS
1.0
mA
all banks idle, CS ≥ VIHmin, CKE ≥ VIHmin, all inputs stable
Active power-down standby current:
one bank active, CS ≥ VIHmin, CKE ≤ VILmax,
inputs changing once every two clock cycles
IDD3P
1.0
mA
Active power-down standby current with clock stop:
IDD3PS
0.5
mA
one bank active, CS ≥ VIHmin, CKE ≤ VILmax, all inputs stable
Active non power-down standby current:
one bank active, CS ≥ VIHmin, CKE ≥ VIHmin,
inputs changing once every two clock cycles
IDD3N
15
mA
Active non power-down standby current with clock stop:
IDD3NS
1.5
mA
one bank active, CS ≥ VIHmin, CKE ≥ VIHmin, all inputs stable
Operating burst read current:
all banks active; continuous burst read,
IDD4
45
mA
inputs changing once every two clock cycles
Auto-Refresh current:
tRC = tRCmin, “burst refresh”,
inputs changing once every two clock cycles
IDD5
90
mA
Self Refresh current:
IDD6
self refresh mode, CS ≥ VIHmin, CKE ≤ VILmax, all inputs stable
Deep Power Down current
IDD7
see Table 22
20
µA
1) 0 °C ≤ TC ≤ 70 °C (comm.); -25 °C ≤ TC ≤ 85 °C (ext.); VDD = VDDQ = 1.8 V ± 0.15 V;
Recommended Operating Conditions unless otherwise noted
2) These values are measured with tCK = 7.5 ns
3) All parameters are measured with no output loads.
Notes
2)3)
2)
–
2)
–
2)
–
2)
–
2)3)
2)
–
–
Data Sheet
46
V1.4, 2004-04-30