English
Language : 

TC1736 Datasheet, PDF (105/123 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1736
5.3.4 Power, Pad and Reset Timing
Electrical Parameters
Table 14 Power, Pad and Reset Timing Parameters
Parameter
Symbol
Values
Unit Note /
Min.
Typ. Max.
Test Condition
Min. VDDP voltage to
ensure defined pad
states1)
VDDPPA CC 0.6
Oscillator start-up time2) tOSCS CC –
Minimum PORST active tPOA
time after power
supplies are stable at
operating levels
SR 10
––
V–
– 10 ms –
––
ms –
ESR0 pulse width
tHD CC program –
–
mable3)5)
fSYS –
PORST rise time
Setup time to PORST
rising edge4)
tPOR
tPOS
SR –
SR 0
– 50 ms –
––
ns –
Hold time from PORST tPOH SR 100
rising edge
––
ns TESTMODE
TRST
Setup time to ESR0
rising edge
tHDS SR 0
––
ns –
Hold time from ESR0
rising edge
tHDH SR 16 ×
–
1/fSYS5)
Ports inactive after
tPIP CC –
–
PORST reset active6)7)
–
ns HWCFG
150 ns –
Ports inactive after
tPI
ESR0 reset active (and
for all logic)
CC –
– 8 × ns –
1/fSYS
Power on Reset Boot tBP CC –
Time8)
– 2.5 ms –
Application Reset Boot tB
Time9)
CC 150
–
960 µs fCPU=80MHz
1.7 ms fCPU=40MHz
1) This parameter is valid under assumption that PORST signal is constantly at low level during the power-
up/power-down of the VDDP.
Data Sheet
101
V1.1, 2009-08