HDMP-1012 Datasheet, PDF (12/42 Pages) Agilent(Hewlett-Packard) – 4Low Cost Gigabit Rate Transmit/Receive Chip Set | |||
|
◁ |
HDMP-1012 (Tx), HDMP-1014 (Rx)
DC Electrical Specifications
Tc = 0°C to +85°C, GND = Ground, VEE = -4.5 V to -5.5 V
Symbol
Parameter
Units Min. Typ.
VIH,ECL
VIL,ECL
ECL Input High Voltage Level, Guaranteed high signal
for all inputs
ECL Input Low Voltage Level, Guaranteed low signal
for all inputs
mV -1150
mV
VOH,ECL
ECL Output High Voltage Level, Terminated with
300 ⦠to -2.0 V
mV -1050
VOL,ECL ECL Output Low Voltage Level, Terminated with
mV
300 ⦠to -2.0 V
VIP,H50
VDC,BLL
VOP,BLL
H50 Input Peak-To-Peak Voltage
BLL Output Bias Voltage Level
BLL Output Peak-To-Peak Voltage, Terminated
with 50 â¦, ac coupled
mV 200
mV
-900
mV
+600
IEE,Tx Transmitter VEE Supply Current, with HCLKSEL off
mA
Tc = 50°C
+403
IEE,Rx
Receiver VEE Supply Current, Tc = 50°C
mA
+512
Note:
1. BLL outputs are measured with external 150 ⦠pull-up resistors to ground. Refer to Figure 23 for additional information.
Max.
-1500
-1600
HDMP-1012 (Tx), HDMP-1014 (Rx)
AC Electrical Specifications
Tc = 25°C
Symbol
Parameter
Units Min. Typ.
tr,ECL
ECL Rise Time, Terminated with 300 ⦠to -2.0 V
nsec
1
tf,ECL
ECL Fall Time, Terminated with 300 ⦠to -2.0 V
nsec
4.5
tr, BLL
BLL Rise Time, Terminated with 50 â¦, ac coupled
psec
200
tf,BLL
BLL Fall Time, Terminated with 50 â¦, ac coupled
psec
170
VSWRi,H50 H50 Input VSWR
2:1
VSWRo,BLL BLL Output VSWR
2:1
Note:
1. BLL outputs are measured with external 150 ⦠pull-up resistors to ground. Refer to Figure 23 for additional information.
Max.
HDMP-1012 (Tx), HDMP-1014 (Rx)
Typical Lock-Up Time
Tc = 25°C
DIV1
DIV0
HDMP-1012, msec
HDMP-1014, msec
0
0
2.0
2.2
0
1
3.0
3.2
1
0
4.5
4.7
1
1
8.0
11.0
Note:
1. Measured in Local Loop-Back mode with the state machine engaged and 0 cable length.
584
LINK[1], msec
2.5
3.5
5.0
12.0
|
▷ |