English
Language : 

HDMP-1012 Datasheet, PDF (12/42 Pages) Agilent(Hewlett-Packard) – 4Low Cost Gigabit Rate Transmit/Receive Chip Set
HDMP-1012 (Tx), HDMP-1014 (Rx)
DC Electrical Specifications
Tc = 0°C to +85°C, GND = Ground, VEE = -4.5 V to -5.5 V
Symbol
Parameter
Units Min. Typ.
VIH,ECL
VIL,ECL
ECL Input High Voltage Level, Guaranteed high signal
for all inputs
ECL Input Low Voltage Level, Guaranteed low signal
for all inputs
mV -1150
mV
VOH,ECL
ECL Output High Voltage Level, Terminated with
300 Ω to -2.0 V
mV -1050
VOL,ECL ECL Output Low Voltage Level, Terminated with
mV
300 Ω to -2.0 V
VIP,H50
VDC,BLL
VOP,BLL
H50 Input Peak-To-Peak Voltage
BLL Output Bias Voltage Level
BLL Output Peak-To-Peak Voltage, Terminated
with 50 Ω, ac coupled
mV 200
mV
-900
mV
+600
IEE,Tx Transmitter VEE Supply Current, with HCLKSEL off
mA
Tc = 50°C
+403
IEE,Rx
Receiver VEE Supply Current, Tc = 50°C
mA
+512
Note:
1. BLL outputs are measured with external 150 Ω pull-up resistors to ground. Refer to Figure 23 for additional information.
Max.
-1500
-1600
HDMP-1012 (Tx), HDMP-1014 (Rx)
AC Electrical Specifications
Tc = 25°C
Symbol
Parameter
Units Min. Typ.
tr,ECL
ECL Rise Time, Terminated with 300 Ω to -2.0 V
nsec
1
tf,ECL
ECL Fall Time, Terminated with 300 Ω to -2.0 V
nsec
4.5
tr, BLL
BLL Rise Time, Terminated with 50 Ω, ac coupled
psec
200
tf,BLL
BLL Fall Time, Terminated with 50 Ω, ac coupled
psec
170
VSWRi,H50 H50 Input VSWR
2:1
VSWRo,BLL BLL Output VSWR
2:1
Note:
1. BLL outputs are measured with external 150 Ω pull-up resistors to ground. Refer to Figure 23 for additional information.
Max.
HDMP-1012 (Tx), HDMP-1014 (Rx)
Typical Lock-Up Time
Tc = 25°C
DIV1
DIV0
HDMP-1012, msec
HDMP-1014, msec
0
0
2.0
2.2
0
1
3.0
3.2
1
0
4.5
4.7
1
1
8.0
11.0
Note:
1. Measured in Local Loop-Back mode with the state machine engaged and 0 cable length.
584
LINK[1], msec
2.5
3.5
5.0
12.0