S9407-AB-HBK-010, Rev. 2
5.10.2 Application for Qualification
Manufacturers shall submit to NUWC, EMC Branch, Code 3431, Newport, RI, a sample 3/4-
inch size RP2100 end-fitting installed on a 1-foot length of conduit (identified by manufacturer's name
and part number). In addition, drawings showing construction details of all sizes of the RP2100 end-
fitting shall be submitted. The drawings shall be numbered and dated for reference purposes.
5.10.3 Deviations
Deviations from this specification such as change in thread size, material or mechanical
design will be considered if the performance requirements can be met. Most changes will require a
new part number for proper identification. Requests for approval of a modification, and assignment of
a new part number shall be addressed to NUWC, EMC Branch, Code 3431, Newport, RI, telephone
(800)-669-6892 X35540. New part numbers and data will be made available upon request, and will be
included in the next change to this handbook.
5.10.4 Sources
The RP2100- and RP2200-Series fittings must be obtained only from the qualified sources
listed in the Qualified Products List, appendix C. Since the RP2300- through RP2600-Series adapters
are simple threaded fittings, they may be obtained from any source which manufactures them in
accordance with this specification.
5.11 PREPARATION FOR DELIVERY
5.11.1 Identification Label
A printed label or tag, in addition to marking required by paragraph 5.8, shall be furnished with
each fitting. The label shall provide the part number, the manufacturer's name, and any other
information, such as a sketch or instruction, which the manufacturer deems pertinent for proper
installation.
5.11.2 Packaging
Each fitting supplied under this specification shall be individually packaged together with an
identification label (see paragraph 5.11.1) in a transparent plastic bag. The bag shall have an
interlocking seal ("ZIP-LOC" type) or shall be closed by heat sealing. Part number identification on the
label shall be easily visible through the sealed bag.
5.12 DATA SHEETS FOR FITTINGS AND ADAPTERS
The following data sheets, figures 5-1 through 5-23, form a part of this specification. They
include assembly drawings, tables of appropriate data, and part number information.
Information regarding installation methods for these fittings may be obtained from NAVSHIPS
drawing 80064-302-4788653, "Installation Methods for High-Permeability Flexible Conduit Hardware,"
(revision A is the latest revision as of the date of this handbook). Note that this drawing is referenced
for information only and, where discrepancies exist, this handbook takes precedence. Note, for
example, that the "Typical Grounding Method" shown as "Method 10-E" in sheet 010 is superseded by
the method shown in MIL-STD-1310D.