STANDARDS
Federal
FED-STD-66
Steel, Chemical Composition, and
Hardenability
Military
MIL-STD-129
Marking for Shipment and Storage
MIL-STD-130
Identification Marking of U.S. Military
Property
(Copies of specifications, standards, drawings, and publications required by contractors in connection
with specific procurement functions should be obtained from the procuring activity or as directed by
the contracting officer.)
4.3.2 Other Publications
The following documents form a part of this specification to the extent specified herein. Unless
otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply.
American Society for Testing and Materials (ASTM)
SAE AMS 2404C
Electroless Nickel Plating
National Bureau of Standards
Handbook H28
Screw-Thread Standards for Federal
Services (Parts I & II)
4.4 CONSTRUCTION
4.4.1 Function
A transition fitting provides the physical connection between flexible metal conduit and an
electrical connector or fitting. An accessory fitting provides the physical connection between flexible
conduit and a bulkhead or panel, and provides the means for coupling two lengths of conduit together.
This type of transition fitting requires the use of a stainless-steel cylindrical end-fitting which is
brazed directly to the braid of the flexible conduit. The other components of the transition fitting are
then attached to the end-fitting with a ferrule which operates by friction. The assembly is made
watertight by O-ring seals.
By comparison, the RP2000-Series reusable fittings (described in section 5) utilize a ferrule
which grips the conduit braid directly by friction, and does not provide for a watertight assembly.
4-2