S9407-AB-HBK-010 Datasheet, PDF (130/276 Pages) Glenair, Inc. – HANDBOOK OF SHIPBOARD ELECTROMAGNETIC SHIELDING PRACTICES
S9407-AB-HBK-010, Rev. 2
Example B (Continued)
PROCEDURE
1
STEP NO.
Repeated step
5
RESULTS AND
CALCULATIONS
S(dB) = S(dB)
susceptor + S(dB)
radiator
S(dB) = 30 + 35
= 65
Repeated step V3(dBV) = -173 + 65
6
= -108
Repeated step 4 (new group number)
7
Repeated step
8
Repeated step
9
5 inches (spacing with both
cables shielded)
Adequate shielding
NOTES
S(dB) susceptor = 30 dB from first step 5.
Rigid metal conduit used for shielding
radiator (see paragraph 6.7.2).
S(dB) radiator = 35 dB from figure 6-7.
V3(dBV) = V1(dBV) + S(dB) of repeated-
step 5.
Figure 6-5 (note 4).
Cable designator is S4-4.
Figure 6-6. Intersection of coordinates R1-4
and S4-4.
Required spacing in repeated-step 8 is
equal to available spacing in step 4. The 5-
inch spacing with shielding must be
maintained as a minimum spacing
requirement.
6-17