Section 3
FLEXIBLE SHIELDING CONDUIT REQUIREMENTS
TABLE OF CONTENTS
Paragraph
3.1
3.2
3.3
3.3.1
3.3.2
3.4
3.4.1
3.4.2
3.4.3
3.4.4
3.4.5
3.4.6
3.4.7
3.5
3.5.1
3.5.2
3.5.3
3.5.4
BACKGROUND ..........................................................................................................
SCOPE .......................................................................................................................
REQUIREMENTS FOR MANUFACTURING AND GOVERNMENT ACCEPTANCE
OF FLEXIBLE SHIELDING CONDUIT .......................................................................
Specification for Flexible Shielding Conduit ...........................................................
Qualified Products List............................................................................................
FLEXIBLE CONDUIT INSTALLATION .......................................................................
Nontopside and Topside Use of Flexible Conduit ..................................................
Grounding Requirements for Flexible Conduit .......................................................
Shielding Effectiveness of Flexible Conduit............................................................
Partial Shielding of Cable .......................................................................................
Bonding and Grounding Methods ...........................................................................
Termination and Coupling of Type 2 Conduit .........................................................
Selection of Flexible Conduit Size ..........................................................................
FLEXIBLE CONDUIT PREPARATION.......................................................................
Cleaning Flexible Conduit.......................................................................................
Forming Flexible Conduit........................................................................................
Cutting Flexible Conduit..........................................................................................
Silver Brazing Fittings to Conduit............................................................................
Page
3-1
3-1
3-1
3-2
3-2
3-2
3-2
3-2
3-3
3-3
3-3
3-4
3-4
3-8
3-8
3-8
3-8
3-10
LIST OF ILLUSTRATIONS
Figure
3-1
3-2
3-3
Method of Grounding Flexible Conduit .......................................................................
Type IV Bond Strap Fabrication Details ......................................................................
Method of Preparing Conduit for Brazing and Cutting ................................................
Page
3-5
3-6
3-9
LIST OF TABLES
Table
3-1
Conduit Dimensions (Inches)......................................................................................
Page
3-7
3-i/3-ii