English
Language : 

S9407-AB-HBK-010 Datasheet, PDF (227/276 Pages) Glenair, Inc. – HANDBOOK OF SHIPBOARD ELECTROMAGNETIC SHIELDING PRACTICES
S9407-AB-HBK-010, Rev. 2
FIGURE 4. Typical pickup coil.
5.2 Preservatives. No preservatives, paints, or coatings shall be applied to the conduit. Conduit
shall be sufficiently clean such that precleaning the conduit will not be necessary in order to obtain a
good metal-to-metal contact between fitting and conduit.
5.3 Identification tags. Each length of conduit shall be separately labeled by means of metal tags
to provide identification information for supply, installation, and repair personnel. These identification
tags are in addition to the conduit markings of 3.9. The tags shall be imprinted with the following
information:
a. EMI SHIELDING CONDUIT.
b. Conduit part number (see 1.2.2).
c. Manufacturer's name.
d. Production-lot number (see 4.5.1).
e. Date of Manufacture.
D-13