MB85RS2MTPF-G Datasheet, PDF (15/28 Pages) Fujitsu Component Limited. – 2 M (256 K × 8) Bit SPI
MB85RS2MT
2. AC Characteristics
Value (TBD)
Parameter
SCK clock frequency
(All commands except
FSTRD command)
Symbol
fCK
Up to 25 MHz operation*
VDD = 1.8 V to 2.7 V
VDD = 2.7 V to 3.6 V
Min
Max
Min
Max
0
25
0
25
SCK clock frequency
(for FSTRD command)
fCK
0
25
0
40
Clock high time
tCH
15
⎯
11
⎯
Clock low time
tCL
15
⎯
11
⎯
Chip select set up time
tCSU
10
⎯
10
⎯
Chip select hold time
tCSH
10
⎯
10
⎯
Output disable time
tOD
⎯
12
-
12
Output data valid time
tODV
⎯
18
-
9
Output hold time
tOH
0
⎯
0
⎯
Deselect time
tD
40
⎯
40
⎯
Data in rising time
tR
⎯
50
-
50
Data falling time
tF
⎯
50
-
50
Data set up time
tSU
5
⎯
5
⎯
Data hold time
tH
5
⎯
5
⎯
HOLD set uptime
tHS
10
⎯
10
⎯
HOLD hold time
tHH
10
⎯
10
⎯
HOLD output floating time
tHZ
⎯
20
⎯
20
HOLD output active time
tLZ
⎯
20
⎯
20
SLEEP recovery time
tREC
⎯
400
⎯
400
* : All commands except FSTRD are applicable to “Up to 25 MHz operation”.
AC Test Condition
Power supply voltage
Operation ambient temperature
Input voltage magnitude
Input rising time
Input falling time
Input judge level
Output judge level
: 1.8 V to 3.6 V
: − 40 °C to + 85 °C
: VDD × 0.7 ≤ VIH ≤ VDD
0 ≤ VIL ≤ VDD × 0.3
: 5 ns
: 5 ns
: VDD/2
: VDD/2
Unit
MHz
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
μs
DS501-00023-0v01-E
15