English
Language : 

MC35XS3400 Datasheet, PDF (6/45 Pages) Freescale Semiconductor, Inc – Quad High Side Switch (Quad 35mΩ)
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics
Characteristics noted under conditions 6.0V ≤ VPWR ≤ 20V, 3.0V ≤ VDD ≤ 5.5V, -40°C ≤ TA ≤ 125°C, GND = 0V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUTS
Battery Supply Voltage Range
Fully Operational
Extended mode(7)
Battery Clamp Voltage(8)
VPWR Operating Supply Current
Outputs commanded ON, HS[0 : 3] open, IN[0:3] > VIH
VPWR
6.0
–
4.0
–
V
20
28
VPWR(CLAMP)
41
47
53
V
IPWR(ON)
mA
–
6.5
20
VPWR Supply Current
IPWR(SBY)
Outputs commanded OFF, OFF Open-load Detection Disabled,
HS[0 : 3] shorted to the ground with VDD= 5.5V
–
WAKE > VIH or RST > VIH and IN[0:3] < VIL
mA
6.0
8.0
Sleep State Supply Current
IPWR(SLEEP)
μA
VPWR = 12V, RST = WAKE = IN[0:3] < VIL, HS[0 : 3] shorted to the
ground
TA = 25°C
TA = 85°C
–
1.0
5.0
–
–
30
VDD Supply Voltage
VDD Supply Current at VDD = 5.5V
No SPI Communication
8.0MHz SPI Communication(9)
VDD(ON)
3.0
–
5.5
V
IDD(ON)
mA
–
1.6
2.2
–
5.0
–
VDD Sleep State Current at VDD = 5.5V
Over-voltage Shutdown Threshold
Over-voltage Shutdown Hysteresis
Under-voltage Shutdown Threshold(10)
VPWR and VDD Power on Reset Threshold
VDD Supply Failure Threshold ( for VPWR > VPWR(UV) )
Recovery Under-voltage Threshold
OUTPUTS HS0 TO HS3
IDD(SLEEP)
–
–
5.0
μA
VPWR(OV)
28
32
36
V
VPWR(OVHYS)
0.2
0.8
1.5
V
VPWR(UV)
3.3
3.9
4.3
V
VSUPPLY(POR)
0.5
–
0.9
VPWR(UV)
VDD(FAIL)
2.2
2.5
2.8
V
VPWR(UV)_UP
3.4
4.1
4.5
V
Output Drain-to-Source ON Resistance (IHS = 2.0A, TA = 25°C)
VPWR = 4.0V
VPWR = 6.0V
VPWR = 10V
VPWR = 13V
RDS(ON)_25
–
–
–
–
mΩ
–
100
–
55
–
35
–
35
Notes
7. In extended mode, the functionality is guaranteed but not the electrical parameters. From 4.0V to 6.0V voltage range, the device is only
protected with the thermal shutdown detection.
8. Measured with the outputs open.
9. Typical value guaranteed per design.
10. Output will automatically recover with time limited autoretry to instructed state when VPWR voltage is restored to normal as long as the
VPWR degradation level did not go below the under-voltage power-ON reset threshold. This applies to all internal device logic that is
supplied by VPWR and assumes that the external VDD supply is within specification.
35XS3400
6
Analog Integrated Circuit Device Data
Freescale Semiconductor