General
the pads. If this limit cannot be observed then a current limiting resistor is required. The negative DC injection current
limiting resistor is calculated as R=(VDIO_MIN-VIN)/|IIC|.
2. Analog pins are defined as pins that do not have an associated general purpose I/O port function.
3. All analog pins are internally clamped to VSS and VDD through ESD protection diodes. If VIN is greater than VAIO_MIN
(=VSS-0.3V) and VIN is less than VAIO_MAX(=VDD+0.3V) is observed, then there is no need to provide current limiting
resistors at the pads. If these limits cannot be observed then a current limiting resistor is required. The negative DC
injection current limiting resistor is calculated as R=(VAIO_MIN-VIN)/|IIC|. The positive injection current limiting resistor is
calcualted as R=(VIN-VAIO_MAX)/|IIC|. Select the larger of these two calculated resistances.
5.2.2 LVD and POR operating requirements
Table 2. LVD and POR operating requirements
Symbol
VPOR
VLVDH
VLVW1H
VLVW2H
VLVW3H
VLVW4H
VHYSH
VLVDL
VLVW1L
VLVW2L
VLVW3L
VLVW4L
VHYSL
VBG
tLPO
Description
Falling VDD POR detect voltage
Falling low-voltage detect threshold — high
range (LVDV=01)
Low-voltage warning thresholds — high range
• Level 1 falling (LVWV=00)
• Level 2 falling (LVWV=01)
• Level 3 falling (LVWV=10)
• Level 4 falling (LVWV=11)
Low-voltage inhibit reset/recover hysteresis —
high range
Falling low-voltage detect threshold — low range
(LVDV=00)
Low-voltage warning thresholds — low range
• Level 1 falling (LVWV=00)
• Level 2 falling (LVWV=01)
• Level 3 falling (LVWV=10)
• Level 4 falling (LVWV=11)
Low-voltage inhibit reset/recover hysteresis —
low range
Bandgap voltage reference
Internal low power oscillator period
factory trimmed
Min.
0.8
2.48
2.62
2.72
2.82
2.92
—
1.54
1.74
1.84
1.94
2.04
—
0.97
900
Typ.
1.1
2.56
2.70
2.80
2.90
3.00
±80
1.60
1.80
1.90
2.00
2.10
±60
1.00
1000
Max.
1.5
2.64
2.78
2.88
2.98
3.08
—
1.66
1.86
1.96
2.06
2.16
—
1.03
1100
1. Rising thresholds are falling threshold + hysteresis voltage
Table 3. VBAT power operating requirements
Symbol Description
VPOR_VBAT Falling VBAT supply POR detect voltage
Min.
0.8
Typ.
1.1
Max.
1.5
Unit
Notes
V
V
1
V
V
V
V
mV
V
1
V
V
V
V
mV
V
μs
Unit
Notes
V
K61 Sub-Family Data Sheet Data Sheet, Rev. 3, 2/2012.
Freescale Semiconductor, Inc.
Preliminary
15