English
Language : 

33912 Datasheet, PDF (10/47 Pages) Freescale Semiconductor, Inc – LIN System Basis Chip with DC Motor Pre-driver and Current
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics (continued)
Characteristics noted under conditions 5.5V ≤ VSUP ≤ 18V, -40°C ≤ TA ≤ 125°C for the 33912 and -40°C ≤ TA ≤ 85°C for the
34912, unless otherwise noted. Typical values noted reflect the approximate parameter mean at TA = 25°C under nominal
conditions, unless otherwise noted.
Characteristic
HIGH SIDE OUTPUTS HS1 AND HS2 PINS (HS1, HS2)
Symbol
Min
Typ
Max
Unit
Output Drain-to-Source On Resistance
TJ = 25°C, ILOAD = 50mA; VSUP > 9.0V
TJ = 150°C, ILOAD = 50mA; VSUP > 9.0V(26)
TJ = 150°C, ILOAD = 30mA; 5.5V < VSUP < 9.0V(26)
Output Current Limitation(27)
0V < VOUT < VSUP - 2.0V
Open Load Current Detection(28)
Leakage Current
-0.2V < VHSX < VS2 + 0.2V
Short-circuit Detection Threshold(29)
5.5V < VSUP < 27V
Over-temperature Shutdown(30), (35)
Over-temperature Shutdown Hysteresis(35)
LOW SIDE OUTPUTS LS1 AND LS2 PINS (LS1, LS2)
RDS(ON)
–
–
–
Ω
–
7.0
–
10
–
14
ILIMHSX
mA
60
120
250
IOLHSX
ILEAK
–
5.0
7.5
mA
µA
–
–
10
VTHSC
V
VSUP -2.0
–
–
THSSD
150
165
180
°C
THSSD_HYS
–
10
–
°C
Output Drain-to-Source On Resistance
TJ = 25°C, ILOAD = 150mA, VSUP > 9.0V
TJ = 125°C, ILOAD = 150mA, VSUP > 9.0V
TJ = 125°C, ILOAD = 120mA, 5.5V < VSUP < 9.0V
Output Current Limitation(31)
2.0V < VOUT < VSUP
Open Load Current Detection(32)
Leakage Current
-0.2V < VOUT < VS1
RDS(ON)
–
–
–
Ω
–
2.5
–
4.5
–
10
ILIMLSX
IOLLSX
ILEAK
mA
160
275
350
–
8.0
12
mA
µA
–
–
10
Active Output Energy Clamp
IOUT = 150mA
VCLAMP
V
VSUP +2.0
–
VSUP +5.0
Short-circuit Detection Threshold(33)
5.5V < VSUP < 27V
VTHSC
V
2.0
–
–
Over-temperature Shutdown(34), (35)
Over-temperature Shutdown Hysteresis(35)
TLSSD
150
165
180
°C
TLSSD_HYS
–
10
–
°C
Notes
26. This parameter is production tested up to TA = 125°C and guaranteed by process monitoring up to TJ = 150°C..
27. When over-current occurs, the corresponding high side stays ON with limited current capability and the HSxCL flag is set in the HSSR.
28. When open load occurs, the flag (HSxOP) is set in the HSSR.
29. When short-circuit occurs and if HVSE flag is enabled, both HS automatic shutdown.
30. When over-temperature shutdown occurs, both high sides are turned off. All flags in HSSR are set.
31. When over-current occurs, the corresponding low side stays ON with limited current capability and the LSxCL flag is set in the LSSR.
32. When open load occurs, the flag (LSxOP) is set in the LSSR.
33. When short-circuit occurs and if HVSE Flag is enabled, both LS automatic shutdown
34. When over-temperature shutdown occurs, both low sides are turned off. All flags in LSSR are set.
35. Guaranteed by characterization but not production tested
33912
10
Analog Integrated Circuit Device Data
Freescale Semiconductor