English
Language : 

STC3500 Datasheet, PDF (40/48 Pages) Connor-Winfield Corporation – INTEGRATED - STRATUM 3 TIMING SOURCE
Application Notes continued
Sel0-3 - Write to the appropriate values for the desired reference selection and operating mode, as shown below:
Reference / Mode
Free Run
Lock to Ref1
Lock to Ref2
Lock to Ref3
Lock to Ref4
Lock to Ref5
Lock to Ref6
Lock to Ref7
Lock to Ref8
Hold Over
Hardware Reference Selection and Mode Control
Table 12
Sel3
Sel2
Pin
Sel1
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
Sel0
0
1
0
1
0
1
0
1
0
1
LOS, LOL, and Hold_Avail are status indication outputs. Their use is at the discretion of the application. See Operating
Modes, Reference Input Quality Mode, and Pin Description sections for details of their operation.
In Hardware Control mode, the Sync_8K and Sync_2K signals default to 50% duty cycle, and DPLL bandwidth/ phase
buildout default to stratum 3.
Preliminary Data Sheet: TM060 Page 40 of 48 Rev: P06 Date: 11/22/04
© Copyright 2001 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice