4-Level FSK Modem Data Pump
5. Application
Page 33 of 50
MX929B PRELIMINARY INFORMATION
5.1 Transmit Frame Example
The operations needed to transmit a single Frame consisting of Symbol and Frame Sync sequences, and one
each Header, Intermediate and Last blocks are provided below:
1. Ensure that the Control Register has been loaded with a suitable CKDIV value, that the IRQEN and
TX / RX bits of the Mode Register are '1', the RXEYE, PSAVE, and SSIEN bits are '0', and the INVSYM bit
is set appropriately.
2. Read the Status Register to ensure that the BFREE bit is '1', then write 6 Symbol Sync bytes (a preamble)
to the Data Block Buffer and a T24S task to the Command Register.
3. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be '1' and
the IBEMPTY bit should be '0'.
4. Write the 6 byte Frame Sync to the Data Block Buffer and a T24S task to the Command Register.
5. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be '1' and
the IBEMPTY bit should be '0'.
6. Write 3 Station ID bytes to the Data Block Buffer and a TSID task to the Command Register.
7. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be '1' and
the IBEMPTY bit should be '0'.
8. Write 10 Header Block bytes to the Data Block Buffer and a THB task to the Command Register.
9. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be '1' and
the IBEMPTY bit should be '0'.
10. Write 12 Intermediate Block bytes to the Data Block Buffer and a TIB task to the Command Register.
11. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be '1' and
the IBEMPTY bit should be '0'.
12. Write 8 Last Block bytes to the Data Block Buffer and a TLB task to the Command Register.
13. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be ‘1’ and
the IBEMPTY bit should be ‘0’.
14. Wait for another interrupt from the modem, read the Status Register; the IRQ, BFREE and IBEMPTY bits
should be '1'.
Notes:
1. The final symbol of the frame will start to appear approximately 2 symbol times after the Status Register
IBEMPTY bit goes to '1'; a further 16 symbol times should be allowed for the symbol to pass completely
through the RRC filter.
2. The SSYM bits of the Mode Register may be altered at any time to change the transmitted ‘S’ symbols. If
a timing reference is required, then setting the Mode Register SSIEN bit to ‘1’ will cause a PC interrupt
after every ‘S’ symbol transmitted, in which case the PC will have to distinguish between interrupts caused
by the BFREE bit going to ‘1’, and those caused by the SRDY bit being set to ‘1’.
3. Figure 19 and Figure 20 illustrate the host PC routines needed to send a single Frame consisting of
Symbol and Frame Sync patterns, a Station ID Block, a Header block, and any number of Intermediate
blocks and one Last Block. It is assumed that the Tx Interrupt Service Routine Figure 20 is called every
time the MX929B IRQ output line goes low.
©2001 MX-COM, INC.
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480171.003
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies.